Reference Manual

Turbo PMAC/PMAC2 Software Reference
Turbo PMAC Global I-Variables 171
I5049 Data Gathering Period
Range: 0 - 8,388,607
Units: Servo Cycles
Default: 1
I5049 controls how often data is logged from source addresses when data gathering is enabled, in units of
servo interrupt cycles. If I5049 is set to 0, data is logged only once per data gathering command (single-
shot mode).
Note:
Normally, this parameter is set automatically by the PMAC Executive Program’s
gathering and tuning routines.
I5050 Data Gathering Selection Mask 1
Range: $000000 - $FFFFFF
Units: Individual Bits
Default: $000000
I5050 controls which of the 24 potential data sources specified by I5001 to I5024 will be gathered when
data gathering is performed. It is a 24-bit value and each bit controls one potential data source. A 1 in the
I5050 bit enables the gathering of the data source; a 0 in the I5050 bit disables the gathering of the data
source.
The following table shows the relationship between bits of I5050 and the data gathering source address I-
variables:
Bit #
Value
I-Variable Enabled
Bit #
Value
I-Variable Enabled
0
$1
I5001
12
$1000
I5013
1
$2
I5002
13
$2000
I5014
2
$4
I5003
14
$4000
I5015
3
$8
I5004
15
$8000
I5016
4
$10
I5005
16
$10000
I5017
5
$20
I5006
17
$20000
I5018
6
$40
I5007
18
$40000
I5019
7
$80
I5008
19
$80000
I5020
8
$100
I5009
20
$100000
I5021
9
$200
I5010
21
$200000
I5022
10
$400
I5011
22
$400000
I5023
11
$800
I5012
23
$800000
I5024
Note:
Normally, this parameter is set automatically by the PMAC Executive Program’s
gathering and tuning routines.
I5051 Data Gathering Selection Mask 2
Range: $000000 - $FFFFFF
Units: Individual Bits
Default: $000000
I5051 controls which of the 24 potential data sources specified by I5025 to I5048 will be gathered when
data gathering is performed. It is a 24-bit value and each bit controls one potential data source. A 1 in the
I5051 bit enables the gathering of the data source; a 0 in the I5051 bit disables the gathering of the data
source.