Specifications

Chapter 4 Control Registers
4-3
CR# Address Attribute Register name Explanation
#25 H1019 O R/W
Total number of points
which need to be adjusted
Setting range: K2~K20 (Factory setting: K2)
#26 H101A X R/W Adjustment command
CH1: K1~K20
CH2: K21~K40
#27 H101B O R/W
Selecting a point which
needs to be adjusted for
CH1
K1~K19
#28 H101C O R/W
Selecting a point which
needs to be adjusted for
CH2
K1~K19
#29 H101D O R/W
Digital value given to a point
which needs to be adjusted
for CH1 (Low word)
#30 H101E O R/W
Digital value given to a point
which needs to be adjusted
for CH1 (High word)
Digital value given to a point which needs to be
adjusted
#31 H101F O R/W
Digital value given to a point
which needs to be adjusted
for CH2 (Low word)
#32 H1020 O R/W
Digital value given to a point
which needs to be adjusted
for CH2 (High word)
Digital value corresponding to a weight needs to be
adjusted
#33 H1021 O R/W
Weight of a point which
needs to be adjusted for
CH1 (Low word)
#34 H1022 O R/W
Weight of a point which
needs to be adjusted for
CH1 (High word)
#35 H1023 O R/W
Weight of a point which
needs to be adjusted for
CH2 (Low word)
#36 H1024 O R/W
Weight of a point which
needs to be adjusted for
CH2 (High word)
Weight of a weight
#37 H1025 O R/W
Maximum which can be
measured by CH1 (Low
word)
#38 H1026 O R/W
Maximum which can be
measured by CH1 (High
word)
#39 H1027 O R/W
Maximum which can be
measured by CH2 (Low
word)
#40 H1028 O R/W
Maximum which can be
measured by CH2 (High
word)
Users can specify the maximum weight which can
be measured by CH1/CH2. If a weight measured
exceeds the maximum weight, an error code will be
stored.
#41 H1029 X R/W
Storing all setting values
(H’5678)
Storing all setting values, and writing them to the
flash memory in the load cell module used
H0: No action (factory setting)
H’FFFF: All setting values are stored successfully.
H’5678: Writing all setting values to the flash
memory in the load cell module used