Specifications

DVP201/202/211LC-SL Load Cell Module Operation Manual
The purpose of making adjustment is to make the weight measured by a cell correspond to the digital value
displayed in a load cell module. Generally, two points are adjusted. After a system is set up, users can put no
load on the scale. The weight measured is 0 grams when no load is put on the scale. The users can put a given
weight on the scale, and set a digital value corresponding to the weight. The two points are adjusted. For
example, if a load cell sensor which can measure a maximum weight of 10 kg is used, and 1 kg correspond to
K1000, the curve presented will be like the one shown below.
Digital value
(LSB)
Point
K1000 K10000K0
1 kg
10 kg
Adjusting two points
Weight
In addition to the adjustment of two points, a load cell supports the adjustment of multiple points (20 points at
most). A characteristic curve is shown below.
Digital value
(LSB)
Point 1
Weight
K1000
K10000
K0
1 kg
10 kg
Adjusting multiple points
Point 2
Point 3
Point 4
Point 5
5-2