Specification Sheet

Tub and Shower
TRIM ONLY for Tub and Dual Shower unit w/standard
24" Slide Bar handshower and shower diverter valve
with diverter spout-backflow protection provided by
two integral check valves in handshower-requires
separate order of R10700-UNWS Rough-in
Model No: T13H963-25
Polished chrome plated finish - Pressure Balance cartridge - Temperature
only controlled with handle - Field adjustable to limit handle rotation into hot
water zone
Integral checks in the cartridge prevent crossflow between Hot and Cold
water inlets
Non-Removable Blue/Red visual cover indicator for Cold, Mixing and Hot
handle positions
Standard 24" Slide Bar handshower and shower diverter valve with diverter
spout-backflow protection provided by two integral check valves in
handshower ADA Compliant diverter handle
Handshower MAX:1.5 GPM @ 80 PSI (5.7 L/min @ 552 kPa)
Handshower MIN:1.13 GPM @ 45 PSI (4.3 L/min @ 310 kPa)
Spout: - - 1/2" IPS metal spout with pull up diverter
Handle#: 3 - Lever Blade Handle - ADA compliant-57 mm (2.24")
Optional 1753 mm (69") Long Chrome plated Brass Double Spiral Hose
(replaces standard hose)
#6 Shower - 30° Vandal Resistant Cast Wallmount Showerhead
#6 Shower Flow Rate MAX: 1.5 GPM @ 80 PSI (5.7 L/min @ 552 kPa)
#6 Shower Flow Rate MIN: 1.4 GPM @ 45 PSI (5.3 L/min @ 310 kPa)
Optional 914mm(36") stainless steel slide bar to replace standard bar
ASME A112.18.1 / CSA B125.1
Pressure Balance Valve ASSE 1016
Indicates compliance to ICC/ANSI A117.1
Pressure Balance and Diverter lever handles ADA compliant to ICC/ANSI
A117.1/ADA
Handshower backflow protection provided by two integral certified check
valves in series, which operate independently, ASME A112.18.3
Handshower ADA compliant to ICC/ANSI A117.1/ADA
(Contact Delta Representative for State and/or Local Approvals)
(Dimensional drawing on following page)
NOTE FOR SHOWER #6: Not for use as anti-ligtature device.
PAUSE WARNING – FOR T13H9, T13H3 and OPTIONAL Handshower
#2
Plumbing Codes require that showerheads and handshowers provide a
small but continuous flow of water (trickle) when in “PAUSE” mode.
Because of this continuous flow, in certain circumstances pressure
variations in the water line and/or changes in the position of the shower
temperature control handle while in “PAUSE” mode could result in dramatic
changes to the temperature of the water when the shower head or hand
shower is returned to the “ON” position.
ALWAYS point the shower head away from yourself when returning to the
“ON” position and feel the water with your hand before resuming your
shower to ensure the water flow is not too hot or too cold.
DO NOT allow children or others who might not understand this warning to
use the “PAUSE” function.
OPERATION:
Delta reserves the right (1) to make changes to specifications and materials, and (2) to change or discontinue models, both without notice or obligation. Dimensions are for reference.
Measurement may vary plus or minus 6mm(0.25"). Mounting locations are suggested only. Check with local codes for requirements in your area. This spec was produced September 28, 2015.
- 1.0.21155
Page of1 3
Delta Faucet Canada - 395 Matheson Blvd E - Mississauga, Ontario, Canada L4Z 2H2 - (905) 712-3030

Summary of content (3 pages)