OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
1.Check the heater for possible shipping damage. If any is
found, immediately notify the factory.
2.Follow all of the "Precautions".
3.Turn the regulator knob to the "Off" position, then connect the
POL fitting of hose and regulator assembly to the propane
cylinder by rotating the POL nut counterclockwise into the
propane cylinder's valve outlet and securely tighten with a
wrench.
4.Connect the hose to the heater.
5.Securely tighten all gas connections.
6.Open the cylinder's gas valve, turn the regulator knob to "HI"
position and check all gas connections with a soap and water
solution. DO NOT USE A FLAME.
7.Turn the regulator knob to "Off" position, and then close valve
on gas cylinder.
START
1.Follow all installation, ventilation and safety information.
2.Locate the heater on stable and level surface. Protect heater
from wind or strong drafts.
3.Open the cylinder's gas valve, and turn the regulator's knob
to "HI" position.
4.Push in and hold the red fuel button. Push the ignition
button. You may need to push the ignition button multiple
times until the pilot lights.
Note: Hose may be filled with air. If so, keep fuel button
depressed and continue to push tihe ignition button.
5.When the pilot lights, keep the fuel button depressed.
Release the fuel button after 30 seconds, and the main
burner will light.
6.Turn the regulator knob to the desired heat setting.
STOP
1.Tightly close the propane cylinder's valve by turning clock-
wise.
2.Continue to operate heater until all fuel in the hose has
burned.
3.Turn the regulator knob to the "Off" position. Wait 20
minutes for the heater to cool before handling heater.
4.Always remove the gas supply hose from the heater and the
propane cylinder after each use.
RESTART AFTER SAFETY SHUTDOWN
1.Securely close valve at propane cylinder.
2.Wait 5 minutes.
3.Restart following "Start" procedure.
MAINTENANCE AND STORAGE
1.The heater should be inspected before each use, and at
least annually by a qualified person.
2.Before each use, check the soft "O" ring seat at the bullnose
of the POL fitting. If the "O" ring is cut, scuffed, or otherwise
damaged, replace it with part number 6681.
3.Turn off the gas at the LP-gas supply cylinder(s) when the
heater is not in use.
4.When the heater is to be stored indoors, the connection
between the LP-gas supply cylinder(s) and the heater must
be disconnected and the cylinder(s) removed from the heater
and stored out of doors and in accordance with Chapter 5 of
the standard for Storage and Handling of Liquefied
Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural
Gas and Propane Installation Code.
SERVICING
A hazardous condition may result if a heater is used that has
been modified or is not functioning properly. When the heater is
working properly:
* The flame is contained within the heater.
* The flame is essentially blue with perhaps some yellow
tipping.
* There is no strong disagreeable odor, eye burning or other
physical discomfort.
* There is no smoke or soot internal or external to the heater.
* There are no unplanned or unexplained shut downs of the
heater.
The parts lists and exploded view show the heater as it was
constructed. Do not use a heater which is different from that
shown. In this regard, use only the hose, regulator and cylinder
connection fitting (called a POL fitting) supplied with the heater.
IMPORTANT Match the color stripe on the hangtag attached to
the hose assembly with the color on the label located near the
propane inlet fitting on the heater. Do not use alternates. For this
heater, the regulator must be set as shown in "specifications". If
there is any uncertainty about the regulator setting, have it
checked.
A heater which is not working right must be repaired, but only by
a trained, experienced service person. To find the service center
closest to you, visit our website at www.scheuco.com.or call
(888) 619-7060.
You may also obtain in-warranty or out-of-warranty service by
taking the product to your local service center.
In-warranty products will be repaired with no charge for either
parts or labor. Please include a brief statement indicating date,
place of purchase, the nature of the problem and proof of
purchase.
Out-of-warrranty products will be repaired with a charge for parts
and labor.
SIZE AND CAPACITY OF PROPANE CYLINDERS REQUIRED
The chart below shows the approximate size of the cylinder
required for heater. To use chart:
1. Select the lowest air temperature expected (at bottom of chart).
2. Move straight up to time of operation desired (left side of chart).
3. Read the cylinder size required.
Models