UnVenTed (VenT-Free) Gas FirePlace sysTem VsGF28nTF, VsGF28PTF
Table Of Contents
- Safety Information
- Local Codes
- Product Identification
- Unpacking
- Product Features
- Air For Combustion and Ventilation
- Installation
- Operating Fireplace
- Inspecting Burners
- Cleaning and Maintenance
- Wiring Diagram
- Specifications
- Troubleshooting
- Replacement Parts
- Technical Service
- Service Hints
- Accessories
- Illustrated Parts Breakdown and Parts List
- Warranty Information
www.desatech.com
119303-01A
21
LOGS
• If you remove logs for cleaning, refer to Install-
ing Logs, pages 16, to properly replace logs.
• Replace log(s) if broken or chipped (dime-sized
or larger).
Figure 34 - Pilot Inlet Air Hole
Burner
Tube
Pilot
Assembly
Pilot Air
Inlet Hole
Ports/
Slots
CLEANING AND
MAINTENANCE
Continued
SPECIFICATIONS
• Rating (Variable) 21,000/28,000 Btu/Hr
• Type Gas Natural Gas
• Ignition Piezo
• Pressure Manifold 3.4" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 10.5"
Minimum* 5"
• Shipping Weight 100 lbs.
* For input adjustment
• Rating (Variable) 23,000/28,000 Btu/Hr
• Type Gas Propane/LP
• Ignition Piezo
• Pressure Manifold 7.9" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 14"
Minimum* 11"
• Shipping Weight 100 lbs.
* For input adjustment
WIRING DIAGRAM
-
Red
Variable
Fan Switch
Fan Switch
(N.O.)
Green
White
On
110/115
V.A.C.
Blower
Motor
Black
Off
1
2
Black
Blue