Relay 2: End of cycle relay
Relay 3: Optional N2 purge event
Relay 4: Optional N2 maintain event
Table 2. Program Page Menu Items and Explanation.
Menu Item
Display
Description
Ramp Time Seg 1
Pro-1 Seg-1 Ramp Time
Ramp time for segment 1 of profile
Event 1 Set Value
3
Pro-1 Seg-1 Ramp Event 1
Event 1 setting for segment 1 ramp of profile
Event 2 Set Value
3
Pro-1 Seg-1 Ramp Event 2
Event 2 setting for segment 1 ramp of profile
Event 3 Set Value
3
Pro-1 Seg-1 Ramp Event 3
Event 3 setting for segment 1 ramp of profile
Event 4 Set Value
3
Pro-1 Seg-1 Ramp Event 4
Event 4 setting for segment 1 ramp of profile
Soak Temp Seg 1
Pro-1 Seg 1 Soak Temp
Soak temperature for segment 1 of profile
Soak Time Seg 1
Pro-1 Seg 1 Soak Time
Soak time for segment 1 of profile
Event 1 Set Value
3
Pro-1 Seg-1 Soak Event 1
Event 1 setting for segment 1 soak of profile
Event 2 Set Value
3
Pro-1 Seg-1 Soak Event 2
Event 2 setting for segment 1 soak of profile
Event 3 Set Value
3
Pro-1 Seg-1 Soak Event 3
Event 3 setting for segment 1 soak of profile
Event 4 Set Value
3
Pro-1 Seg-1 Soak Event 4
Event 4 setting for segment 1 soak of profile
(Repeat for segments 2-8, until ramp = 00:00)
High Limit Setpoint
Profile-1 Hi-Lim SP
High limit setpoint for profile
4
Loop From
Profile-1 Loop From Seg
To start a loop action in a profile
Loop To
Profile-1 Loop To Seg
To end a loop action in a profile
Loop Count
Profile-1 Loop Number
Number of times to execute loop
Profile Link
Profile-1 Link To Pro
To jump from this profile to another
Guaranteed Soak
Profile-1 Guar Band
Guaranteed soak band for profile
3
Available only if optional relay outputs are installed (repeat all for Profiles 2-8).
4
Set to Band to use the high limit band feature.