User Manual

TROUBLESHOOTING Stackable LCC/LCD Oven Owners Manual
44 Version 1.1
Copyright © 2012 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
7. Troubleshooting: Error Messages and Alarm
Table 7 lists the more common error messages, the possible problems and remedies.
Table 7. Error Messages and Next Steps.
Alarm Status
Possible Problem
Next Step
Hi-Limit LED flashing
Problem with thermocouple
Hi-limit setpoint has been
exceeded.
Once the problem has corrected,
press Reset.
Soak LED flashing
Oven temperature has not
entered (or dropped out of) the
soak band and the soak timer
has stopped
Program a slower ramp rate or if
oven is not heating check heater
circuit.
Top LED displays
OPEN and lower LCD
displays CONTROL
SENS ERR
Control thermocouple is
disconnected or broken
Repair or replace the thermocouple.
Lower LCD displays HI
LIM SENS ERR
Hi limit thermocouple is
disconnected or broken
Repair or replace the thermocouple.
Lower LCD displays
HIGH LIMIT ALARM
Hi limit temperature setpoint
has been exceeded
Determine if:
the setting is too close to the
setpoint
the SSR is defective
calibration is incorrect
The lower LCD intermittently displays HL Temp. This is not an
error message, but the Hi limit thermocouple temperature
reading.