Use and Care Manual

ENGLISH
10
Fig.H
21
5
Work Stop Adjustment (Fig. A, H)
To support large workpieces, the work stop should be
lowered following these steps:
1. Loosen the two screws
21
, shown in FigureH, with the
hex wrench
10
provided.
2. Move the work stop
5
to the desiredposition.
3. Securely tighten screws
21
.
Installing the Brush and Brush Cap (Fig. I)
WARNING: To reduce the risk of serious personal
injury, turn tool off and remove the battery pack
before making any adjustments or removing/
installing attachments or accessories. An
accidental start-up can causeinjury.
NOTE: The brush/brush cap assembly is available at extra
cost from your local dealer or authorized servicecenter.
1. Turn the saw over and place it on a workbench or table
with the handle to theright.
2. First, slide the brush
22
into the slot as seen in FigureI,
then place the brush cap
23
over top and screw
securely intoplace.
Fig.I
22
23
OPERATION
WARNING: To reduce the risk of serious personal
injury, turn unit off and remove the battery pack
before making any adjustments or removing/
installing attachments or accessories. An
accidental start-up can causeinjury.
There are certain applications for which this tool
wasdesigned.
This band saw is designed to cut various types of material
up to 4–3/4" (120.7 mm) diameter or 5" (127 mm) x 4–3/4"
(120.7 mm) rectangular shape at90º.
WARNING: Thoroughly remove any oil or grease
from the workpiece before securing in a vise or other
clamping device. If the workpiece is not secure, it may
come loose during the cutting and/or cause breakage,
which may result in serious personalinjury.
Installing and Removing the Battery Pack
(Fig. J)
NOTE: For best results, make sure your battery pack is
fullycharged.
To install the battery pack
19
into the tool handle, align the
battery pack with the rails inside the tool’s handle and slide
it into the handle until the battery pack is firmly seated in
the tool and ensure that it does notdisengage.
To remove the battery pack from the tool, press the release
button
20
and firmly pull the battery pack out of the tool
handle. Insert it into the charger as described in the charger
section of thismanual.
Fig.J
19
20
Proper Hand Position (Fig. K)
WARNING: To reduce the risk of serious personal injury,
ALWAYS use proper hand position as shown.
WARNING: To reduce the risk of serious personal
injury, ALWAYS hold securely in anticipation of a
suddenreaction.
Proper hand position requires one hand on the main
handle
4
and one hand on the fixed bail handle
1
.