PBX Integration Board User's Guide

Dialogic
®
PBX Integration Board User’s Guide
4.2. Siemens ROLM PBX
The ROLM product family includes three generations of ROLM and related
PBXs:
1. The original ROLM
2. IBM ROLM 9751 series
3. Siemens Hicom 300 with the appropriate interface cards
The Dialogic
®
PBX Integration Board emulating the ROLM 400 telephone
can be used with these switches. The ROLM PBXs use digital signaling to
control their station sets and digitized voice.
The Dialogic
®
PBX Integration Board has either four or eight channels that
can be connected directly to a station module in a Siemens ROLM PBX. The
PBX switch has many standard features that are supported by the PBX
Integration Board, such as:
direct inward dialing (DID)
speed dialing
hunt groups
message waiting indication
user programmable feature keys
called/calling number identification
call forwarding
4.2.1. Siemens ROLM Programming Requirements
There are specific switch programming requirements that apply if using a
Dialogic
®
PBX Integration Board with a Siemens ROLM PBX. Pay attention
to set these features exactly (and assigned to the right keys) so that the PBX
Integration Board and the Dialogic
®
Unified API can function correctly.
All PBX Integration Board ports on a ROLM system must be
programmed as ROLMphone 400 telephones.
LINE must be programmed on Feature Key 09, and the ROLMphone
must be programmed to select this line when going off-hook.
52