User`s guide

Dialogic
®
System Release 6.0 PCI for Windows
®
Release Update, Rev 62 — January 30, 2008 145
Dialogic Corporation
The #0 and #1 represent the logical ID or board ID. The slot 1/11 and slot 2/3 represent
the bus and slot numbers, which identify the unique location of the boards. See the
following valid values for the Name and Type parameters.
Warning: Do not change the board Name or Type. The optimum settings are specific to the
category of board (board name and architecture type). The values for these parameters
are only shown to help you identify specific boards.
Valid DM3 Board names for Name parameter:
DI/0408-LS-A-R2
DMV160LP
Valid Springware Board names for Name parameter:
D/41JCTls
D/120JCT-LS-Rev 2
Valid values for Type parameter:
DM3
Springware
Channel Identification
The Channel number keyword identifies the channel on the board. The channel
identification line is followed by the optimum coefficient settings that apply to the channel.
The format of the channel identification line is shown through the following example:
<Channel number="1">
This specifies channel number 1.
Note: Do not attempt to edit the optimum coefficient values.
Terminator for End of Board Data Section
Each board section is terminated by an end-board line as follows:
</BOARD>
1.43.5 LineAdapt Utility Command Line Interface
For the location of the utility program executable and its files, see Section 1.43.4.1,
“Location and Description of the Utility and Component Files”, on page 139.
This section provides information on the following topics:
Prompting Mode and Command Mode
Discovery, Initialization, and Storage of Optimum Settings