User`s guide

Dialogic
®
System Release 6.0 PCI for Windows
®
Release Update, Rev 62 — January 30, 2008 234
Dialogic Corporation
1.60.3 Modifying Default Threshold Values for New Alarms
If desired, you can change the default threshold value of a new T1/E1 alarm by adding a
parameter in the CONFIG file that corresponds to the PCD file in use on your board. The
change is made per span. After threshold parameters are added, generate an updated
FCD and start system services on the board. If threshold parameters are not added,
default threshold values are in effect. See the Dialogic
®
DM3 Architecture PCI Products
on Windows
®
Configuration Guide for more information on CONFIG files, PCD files, and
FCD files.
To modify default threshold values for E1 alarms, add one or more of the following
parameters (sample value of 100 shown) to the [lineAdmin.x] section of a CONFIG file:
SetParm=0x1639,100 ! BPVS threshold range 0 - 255, default 255
SetParm=0x163c,100 ! ECS threshold range 0 - 255, default 0
SetParm=0x163d,100 ! CECS threshold range 0 - 255, default 255
To modify default threshold values for T1 alarms, add one or more of the following
parameters (sample value of 100 shown) to the [lineAdmin.x] section of a CONFIG file:
SetParm=0x1639,100 ! BPVS threshold range 0 - 255, default 255
SetParm=0x163a,100 ! OOF threshold range 0 - 255, default 0
SetParm=0x163b,100 ! FERR threshold range 0 - 255, default 0
SetParm=0x163c,100 ! ECS threshold range 0 - 255, default 0
1.60.4 Support for New Alarms in GCAMS Functions
The new alarms are supported by the GCAMS API functions as documented in the
Dialogic
®
Global Call API Library Reference in the Dialogic
®
System Release 6.0 PCI for
Windows
®
bookshelf.
1.61 Telecom Subsystem Summary Tool (its_sysinfo)
The Telecom Subsystem Summary Tool (its_sysinfo) provides a simple way to collect
information about systems built using Dialogic
®
products. The its_sysinfo tool collects
data from the system on which you execute it and provides information about the system
Table 8. New Alarms for T1 Technology (DM3 Boards)
Alarm Meaning
Default
Threshold
Value
Range
DTT1_BPVS Bipolar violation count saturation 255 0 to 255
DTT1_ECS Frame bit error count saturation 0 0 to 255
DTT1_FERR Two out of four consecutive frame bits
(F bit) in error
0 0 to 255
DTT1_OOF Out of frame error count saturation 0 0 to 255