User`s guide

Dialogic
®
System Release 6.0 PCI for Windows
®
Release Update, Rev 62 — January 30, 2008 263
Dialogic Corporation
Known IPY00008091 31432 Conferencing
(DCB)
The maximum value for the dcb_estconf( ) function
numpty parameter is 24. If you attempt to establish a
conference with more than 58 parties initially by using
the dcb_estconf( ) function with numpty parameter
set to greater than 58, rather than giving an API error,
the driver will fail.
Workaround: To create a conference with greater than
24 parties, use the dcb_estconf( ) function to
create a 24-party conference, and then use the
dcb_addtoconf( ) function to add parties one at a
time. You can have as many parties in a conference
as is supported by your particular board and its
media load.
Known IPY00008269 29634 CPI Fax When a tiff header analyzing utility (tiffhdr.exe) is used
to analyze a tiff file that’s received on a Dialogic
®
CPI
Fax Board running in MH mode (TIFF Group 3 1-D), it
generates an error saying “error 2905 on line 138".
Workaround: Use another encoding than MH.
Known IPY00006204 34764 CSP If the ECCH_CONVERGE parameter is set on a
Dialogic
®
DM3 Board that does not support this
feature, the board fails with error “device busy” and
“SP 2 NOT RESPONDING.” (The only board that
supports the ECCH_CONVERGE parameter is the
Dialogic
®
DMV160LP Board.)
Known D/120JCT-EURO The Dialogic
®
D/120JCT-EURO Board is unable to
detect a standard continuous DISCONNECT tone
(350 Hz, 440 Hz).
Workaround: The DISCONNECT tone can be
detected if FREQUENCY RES is set to “LOW” (125
Hz value). Therefore, select Euro-21 as country for
D/120JCT boards; this has FREQ-LOW as the
default frequency resolution.
Known IPY00022110 22030 D/120JCT-LS Routing LSI resources from the Dialogic
®
D/120JCT
Boards results in heavy noise (echo problem).
Known IPY00007346 29275 D/120JCT-LS When configuring PCM encoding on a system
containing both Dialogic
®
Springware Boards and
Dialogic
®
DM3 Boards, the Dialogic
®
D/120JCT-LS
Boards default to mu-law. When attempting to
reconfigure from configured devices (top level) to A-
law, the D/120JCT-LS Board does not change; it
remains mu-law.
Workaround: Configure PCM encoding for each board
manually.
Known D/120JCT-LS The Dialogic
®
D/120 Rev2 Board supports Japan
Caller ID, but the EC_RESOURCE must be set to ON.
This reduces the density of the board to 8 channels.
The D/120 Rev1 Board does not support Japan Caller
ID.
Table 9. Issues Sorted By Type, Dialogic
®
System Release 6.0 PCI for Windows
®
(Continued)
Issue Type Defect No.
PTR
No.
SU
No.
Dialogic
®
Product(s) or
Component(s)
Description