User`s guide

Dialogic
®
System Release 6.0 PCI for Windows
®
Release Update, Rev 62 — January 30, 2008 264
Dialogic Corporation
Known IPY00008850 31245 D/480JCT-2T1
D/600JCT-2E1
When Global Level PCMEncoding is not set to
“Automatic”, which is the default, it must be set to
match the Board Level PCMEncoding for the Dialogic
®
D/480JCT-2T1 and D/600JCT-2E1 Boards.
Known IPY00021906 21049 D/82JCT-U Call Progress test fails 100% on Dialogic
®
D/82JCT-U
Boards. Explanation: The D/82JCT-U voice
resources cannot be used to provide CPA capability
for other boards.
Known IPY00021905 21029 D/82JCT-U If a voice resource of a Dialogic
®
D/82JCT-U Board is
listening to a front end other than the default (its own),
it may return a disconnected result. Explanation: The
D/82JCT-U Board supports the call progress analysis
feature of dx_dial( ), only when the D/82JCT-U is
using the default TDM routing.
Known IPY00021909 21082 DCM When using Dialogic
®
Global Call SS7, Dialogic
®
SS7
Signaling Boards (PCCS6) can be added manually via
DCM, but DCM doesn't allow the SS7 board to be
used as the SCbus clock master.
Known IPY00022112 22090 Device Naming dx_open( ) causes an application crash with access
violation when the size of name is equal to or more
than 31 characters. Explanation: There is a limitation
on the length of a device name. It can be no longer
than 30 characters.
Known IPY00026634 22919 DI Boards dx_playtone( ) can only play up to 35 unique tones.
Known IPY00020991 20150 DI Boards ms_setvol( ) does not affect the volume level on the
Dialogic
®
DI/SI32 or DI/0408-LS-A Board.
Known IPY00022220 25318 Dialogic System
Service
When starting the Dialogic
®
System Service (DSS) via
the Windows
®
Service Control Manager, a Progress
dialog box may display the following error message:
“Error 1053: The service did not respond to the start or
control request in a timely fashion”
This Progress message appears when any Windows
service started via Service Control Manager takes
more than 3 minutes. The message is misleading
because the DSS may still be in a start pending state
and start completion should occur within 7 additional
minutes. The 3 minute limit is hard-coded by Microsoft
in Windows 2000.
Workaround: Start the DSS using the DCM tool.
Note: Refer to the Microsoft Knowledge Base,
Product Support Services documentation for
further details about Error 1053.
Table 9. Issues Sorted By Type, Dialogic
®
System Release 6.0 PCI for Windows
®
(Continued)
Issue Type Defect No.
PTR
No.
SU
No.
Dialogic
®
Product(s) or
Component(s)
Description