Known
(permanent)
IPY00022342 15033 D/82JCT-U “Parm not set correctly” error for board and channel
parameters. The problem occurs when the
d42_setparm( ) or d42_getparm( ) function is called
simultaneously on multiple threads for the same
channels on the Dialogic
®
D82JCT-U Board. Very
infrequently, the function call will fail.
Workaround: There are several workarounds for the
problem.
Re-issue the d42_setparm( ) or d42_getparm( )
function when the function returns this failure.
Limit calls to d42_setparm( ) or d42_getparm( )
to a single thread in the application.
Implement a semaphore in the application to
serialize calls to these functions in a multithreaded
application.
Known
(permanent)
IPY00022390 19978 DCM The Terminal Server program cannot auto detect
boards on a Windows
®
2000 machine. Explanation:
The Remote DCM is not designed to work via Terminal
Server for security reasons.
Known
(permanent)
IPY00022293 19308 DCM The spandti.prm file is not downloaded by default.
Workaround: Specify this parameter in the
“ParameterFile” in DCM in order for it to take effect.
Table 9. Issues Sorted By Type, Dialogic
®
System Release 6.0 PCI for Windows
®
(Continued)
Issue Type Defect No.
PTR
No.
SU
No.
Dialogic
®
Product(s) or
Component(s)
Description