User`s guide

Dialogic
®
System Release 6.0 PCI for Windows
®
Release Update, Rev 62 — January 30, 2008 289
Dialogic Corporation
Known
(permanent)
IPY00037015 -- UDD Dialogic
®
Diagnostics Software (UDD) reports
download errors when multiple boards are installed in
the same system.
Workaround: When using UDD to test multiple
Dialogic
®
Springware Boards in the same system,
use DCM to disable all boards except the one being
tested.
Resolved IPY00032793 -- 113 Board Deselection For Dialogic
®
DM3 PSTN boards, DCBU switchover
fails when the primary and standby D-channels are
configured on different boards.
Resolved IPY00039538 -- 166 Board Detection Error messages are seen in the Windows
®
Event
Viewer indicating that the RTF server is not running.
This is occurring because none of the Dialogic
®
services have a dependency configured on the RTF
service.
Resolved IPY00037356 -- 148 Board Detection DCM assigns the same physical slot ID to two boards
(in different physical slots).
Resolved IPY00033013 -- 108 Board Detection If the customer installs build 104 or later, and if they
have Dialogic
®
CPI2400_1_T1 and CPI3000_1_E1
boards in their system, and they do a ‘Restore Default’
from the DCM GUI, the name will be changed to
DF240_1_T1 and DF2000_1_E1, respectively. The
change is only in the name displayed in DCM GUI,
and there is no functionality difference.
The same thing can happen if the customer uninstalls
the existing build and installs the build 104 or later.
Resolved IPY00040874 -- 181 Board Download Dialogic
®
DMV1200BTEPE Board fails to start on
Service Update 155.
Resolved IPY00038946 -- 162 Board Download Dialogic
®
JCT Media Boards download failed.
Resolved IPY00038792 -- 162 Board Download Slow download times for Dialogic
®
JCT Media Boards
on high-end machines.
Resolved IPY00038074 -- 154 Board Download The OAMSYSLOG component reports multiple
“DM3FDSP - GetOverlappedResult()[2] timeout for
board 5, Error= 121” entries in RTF logs during load
test.
Resolved IPY00033228 -- 154 Board Download Cannot route voice device if it is not on the same
board as the digital frontend device.
Resolved IPY00035350 -- 134 Call Control While sending NonStandard Control data in an H.323
message, if the input string contains a byte with value
0x00, all the data after this byte will not be sent.
Resolved IPY00034079 -- 125 Call Control After gc_SwapHold( ) function successfully returns,
both Global Call call states were reported as
GCST_CONNECTED.
Resolved IPY00028500 35390 63 Call Logging The cl_open( ) function is not working; it doesn't give
a value to the parameter errno and always returns
zero.
Table 9. Issues Sorted By Type, Dialogic
®
System Release 6.0 PCI for Windows
®
(Continued)
Issue Type Defect No.
PTR
No.
SU
No.
Dialogic
®
Product(s) or
Component(s)
Description