Resolved IPY00028345 35148 64 DM3 Firmware D-channel fails to come up on a back to back setup.
Two spans of NI2 are connected back to back and the
D-channel comes up. When the cable is pulled out, the
network side doesn’t report the D-channel going
down. When the cable is reconnected, the D-channel
doesn't come up.
Resolved IPY00028299 35430 84 DM3 Firmware ANI is not returned when Screening Indicator is set
under DMS protocol.
Resolved IPY00028295 34503 56 DM3 Firmware Application starts getting TDX_ERROR events after
dx_playiottdata( ).
Resolved IPY00028273 32842 70 DM3 Firmware SETUP message without channel ID is not accepted
by the firmware on Dialogic
®
DM/IP Board when the
board is configured as Network side.
Resolved IPY00028244 34159 84 DM3 Firmware The 0x3925 parameter does not appear in the
ml9b_pcires.config file.
Resolved IPY00021322 29294 -- DM3 Firmware Central Processor Failure is returned in the event log
after making a few calls.
Resolved IPY00010545 35967 74 DM3 Firmware Qsig firmware does not send IE information to the
application when the IE length is longer than normal.
Resolved IPY00010472 34532 74 DM3 Firmware When all 95 channels are enabled in NFAS back-to-
back systems using gc_basic_call_model, the system
hangs.
Resolved IPY00010418 35572 63 DM3 Firmware The dx_stopch( ) function does not return
TDX_PLAY(0x81).
Resolved IPY00009611 33998 56 DM3 Firmware Sometimes dx_stopch( ) fails to terminate the voice
activity (play or record), leading to a player or recorder
stuck in a stopping state.
Resolved IPY00009597 32651 18 DM3 Firmware GCEV_ANSWER events are missing when using NI2
(ml2_qsa_ni2).
Resolved IPY00009588 34915 74 DM3 Firmware With pdk_us_mf_io protocol, using immediate start
with wait for dial tone option, 25% of outbound calls fail
with protocol error.
Resolved IPY00009103 33425 18 DM3 Firmware Static-sounding background noise trails voice in
conferences with more than six parties.
Resolved IPY00009080 33144 18 DM3 Firmware GCEV_DROPCALL event is not always returned from
gc_DropCall( ) after call glare has occurred.
Resolved IPY00008779 34575 56 DM3 Firmware Dialogic
®
DM/V160LP firmware crashed running a
load test.
Resolved IPY00007819 33173 84 DM3 Firmware Host ISDN state machine gets out of sync with switch
after 4ESS RESTART messages.