User`s guide

Dialogic
®
System Release 6.0 PCI for Windows
®
Release Update, Rev 62 — January 30, 2008 319
Dialogic Corporation
Resolved IPY00016168 28084 -- ISDN When performing ISDN tracing on all spans in a bulk
call environment, dual span boards can encounter
firmware crashes with just one board running.
Resolved IPY00007887 29513 -- ISDN Under heavy load, firmware assert happens in
vb_util.c when working with ISDN protocols.
Resolved IPY00008535 31333 18 ISDN Protocols The 5ESS protocol firmware on Dialogic
®
JCT Boards
does not handle incoming STATUS messages with a
cause value “Response to Status Enquiry” properly.
Resolved IPY00009183 32625 18 ISDN Q.SIG
Protocol
When the service provider sends a STATUS message
carrying cause value 100 (invalid information element
contents), the board responds with an immediate
disconnect.
Resolved IPY00037319 -- 160 JCT Call Control If a board running ISDN 4ESS receives a CALL
PROGRESS message in which the LOCATION
information element in the Progress Indicator is 1010 -
Location (network beyond interworking point), it sends
back a STATUS message to the switch with Cause
Value 100 (Invalid Information Element Contents).
Resolved IPY00028305 32144 74 Media Voice
Library
When the system is under heavy load, it’s been
observed that anywhere between 2-100 hours, a Voice
channel fails to return a completion event
TDX_RECORD while doing a Record operation. The
application even on calling dx_stopch( ) does NOT
recover the channel and the channel is stuck. This
problem happens on a heavily loaded system and only
affects record operation on a Voice channel. Play
operations work fine. If the application then calls
ATDX_STATE( ) to examine the state of the channel
and for all subsequent calls, the value returned is 7
(“CS_STOPD”).
Resolved IPY00040179 -- 171 Modular Station
Interface (MSI)
SRL_TIMEOUT_ERROR occurs after upgrading from
SU 154 to SU 166. (Results in ms_listen( ) /
ms_unlisten( ) failures.)
Resolved IPY00038551 -- 162 Modular Station
Interface (MSI)
ms_stopfn( ) causes two TSC_MsgReleaseCall
messages to be sent to the Dialogic
®
DM3 Analog
TSP.
Resolved IPY00038433 -- 160 Modular Station
Interface (MSI)
The ms_stopfn( ) function fails to stop the ringing on
a Dialogic
®
DISI32R2 Board.
Resolved IPY00028642 36548 92 Modular Station
Interface (MSI)
The ms_estconf( ) function is not working correctly in
Service Update 74.
Resolved IPY00019148 29058 -- Modular Station
Interface (MSI)
ms_genring( ) will cause an application to crash (in
libdm3msi.dll) if you open the same MSI device twice
and if you execute the ms_genring( ) on the second
device handler.
Workaround: Don't open the MSI devices twice.
Resolved IPY00019145 28944 -- Modular Station
Interface (MSI)
Using MS_RNG_DEFAULT in the ms_genringex( )
function generates “Invalid Ring Cadence” error.
Table 9. Issues Sorted By Type, Dialogic
®
System Release 6.0 PCI for Windows
®
(Continued)
Issue Type Defect No.
PTR
No.
SU
No.
Dialogic
®
Product(s) or
Component(s)
Description