Release Update, Rev 62 — January 30, 2008 337
Dialogic Corporation
Resolved IPY00008215 28550 18 Springware Voice With the Dialogic
®
DTI/240SC Board, when the
inbound application is to receive a call, the calling
(Telco) side receives an error message ‘protocol error’
and the call is dropped.
Resolved IPY00008056 33690 22 Springware Voice Turning Silence Compressed Record on via the
voice.prm file causes distortion on Dialogic
®
D600JCT2E1 Boards, rendering recorded files
unusable. This problem occurs when recording in
8kHz linear format.
Resolved IPY00007937 32318 22 Springware Voice An intermittent problem has been seen when
dx_rec( ) is called synchronously and fails to return
after calling dx_stopch( ) on that channel from
another thread. Even after exceeding the MAXTIME
timeout value for the dx_rec( ), it still leaves the
channel in a hung state.
Resolved IPY00037918 -- 165 SS7 The RSI link goes down intermittently.
Resolved IPY00037767 -- 148 SS7 The GCSS7 library does not generate the
GCEV_MOREINFO event if it receives a SAM
message with only STOP digit (0xf) after the
application has already issued gc_CallAck( ).
Resolved IPY00037632 -- 148 SS7 If there is a delay in the SS7 server picking up
messages from the IPC queue, an
ERROR_IO_PENDING occurs and the SS7 library
terminates the IPC. This causes all the circuits to get
blocked, as there is no more connection with the SS7
service. This is causing the IVRs to get a sudden
circuit block from the switch in all of its SS7 circuits.
Resolved IPY00034404 -- 131 SS7 In GCSS7, initial alarm conditions are not propagated
up to application.
Resolved IPY00033499 -- 115 SS7 Opening of dti devices via GCSS7 library fails.
Resolved IPY00039334 -- 178 Standard Runtime
Library (SRL)
An application crash occurred; the stack trace shows
SRL library at the top of the stack.
Resolved IPY00039155 -- 165 Standard Runtime
Library (SRL)
An application crash occurs with SRL at the top of the
stack; the SRL was not initializing all variables of a
structure for a given thread, which can cause an
access violation.
Resolved IPY00038708 -- 160 Standard Runtime
Library (SRL)
An access violation occurs when application calls
sr_waitevtEx( ) for the same device on multiple
threads.
Resolved IPY00038119 -- 154 Standard Runtime
Library (SRL)
When using a Dialogic
®
D/120JCT-LS Board, calling
the ATDV_ERRMSGP( ) function caused a LIB crash.
The crash occurred when the application called
ATDV_ERR MSGP( ) at the end of fax reception when
fx_rcvfax( ) returns with -1.
Resolved IPY00014187 29372 -- Standard Runtime
Library (SRL)
Synchronous function can become blocked when
sr_waitevt( ) is called from another thread.
Table 9. Issues Sorted By Type, Dialogic
®
System Release 6.0 PCI for Windows
®
(Continued)
Issue Type Defect No.
PTR
No.
SU
No.
Dialogic
®
Product(s) or
Component(s)
Description