User`s guide

Dialogic
®
System Release 6.0 PCI for Windows
®
Release Update, Rev 62 — January 30, 2008 354
Dialogic Corporation
For boards that support continuous speech processing (CSP), set this parameter to OFF
(disabled) and, instead, use the CSPExtraTimeSlot parameter to enable echo
cancellation.
The guideline should be changed to:
For Dialogic® Springware Boards that support continuous speech processing (CSP), set
this parameter to ON (enabled) and also set the CSPExtraTimeSlot parameter to ON.
Update to Section 4.4, Misc Property Sheet, for CSPExtraTimeSlot Parameter
(IPY00041018)
The following guideline for using the CSPExtraTimeSlot parameter is incorrect:
If you enable CSP for a board, do not enable the board’s EC_Resource parameter.
The guideline should be changed to:
If you enable CSP for a Dialogic
®
Springware Board, you must also enable the board’s
EC_Resource parameter.
Update to Section 4.5, TDM Bus Configuration Property Sheet
The information about the DCM parameter Derive Primary Clock From (User
Defined) that is contained in Section 4.5, TDM Bus Configuration Property Sheet,
is replaced by the following:
Derive Primary Clock From (User Defined)
Description: The Derive Primary Clock From (User Defined) parameter specifies the clock
source that the Primary Master FRU uses to drive the Primary Line.
Values:
Default [default]: The value of this parameter is to be determined by the system software. Its
current value is indicated by the Resolved Equivalent.
FrontEnd_1: The Primary Master derives clocking from its own front end network interface.
This value only applies when the TDM Bus Type (Resolved) is set to SCbus and the Primary
Master FRU (Resolved) is a Dialogic
®
Springware Board.
FrontEnd_2: The Primary Master derives clocking from its own second network interface.
This value only applies when the TDM Bus Type (Resolved) is set to SCbus and the Primary
Master FRU (Resolved) is a Springware Board.
FrontEnd_3: Not applicable to Springware Boards.
FrontEnd_4: Not applicable to Springware Boards.
InternalOscillator: The Primary Master derives clocking from its own internal circuitry.
NETREF_1: The Primary Master derives clocking from NETREF_1 (CT Bus only).
NETREF_2: This selection is not supported for this release.
Update to Section 4.6, Country Property Sheet
The information about the DCM parameter Digital Signaling that is included in
Section 4.6, Country Property Sheet, is replaced by the following: