User`s guide

Dialogic
®
System Release 6.0 PCI for Windows
®
Release Update, Rev 62 — January 30, 2008 359
Dialogic Corporation
Update to EC_Resource help topic (IPY00041018)
The following note for using the EC_Resource parameter is incorrect:
For boards that support Continuous Speech Processing (CSP), set this parameter to OFF
(disabled) and, instead, use the CSPExtraTimeSlot parameter to enable echo
cancellation.
The note should be changed to:
For Dialogic
®
Springware Boards that support Continuous Speech Processing (CSP), set
this parameter to ON (enabled) and also set the CSPExtraTimeSlot parameter to ON.
Update to Group One Clock Rate, ..., Group Four Clock Rate parameter help topics
The help topics for the four parameters Group One Clock Rate, ..., Group Four
Clock Rate should each include the following note:
Note: This parameter does not apply when the Bus Type parameter is set to SCbus.
Update to FCDFilename and PCDFilename parameter help topics
The following note is added to the help topics for the FCDFilename and
PCDFilename parameters:
Note: Dialogic
®
HDSI Boards use country-specific PCD and FCD files. Depending on the PCD/FCD
files selected for an HDSI Board, the PCM encoding method will be set to either A-law or mu-law,
based on the default value for that country. If this value is not the same as the TDM Bus Media
Type parameter setting, the HDSI Board will fail to download.
To change the PCM encoding method for the HDSI Board from the default value, you will need to
edit the Encoding parameter in the associated Config file, re-generate the FCD file, and then restart
the system. For additional information about modifying FCD file parameters, see the Dialogic
®
DM3 Architecture PCI Products on Windows
®
Configuration Guide.
Update to PciID parameter help topic (Physical property sheet)
The information in the help topic for the PciID parameter should read as follows:
Description: A positive integer or hexadecimal value in which the lower 5 bits specify a board’s
rotary-switch setting (PCI boards) or the physical slot number location of the board (CompactPCI
boards). The rotary-switch setting for PCI boards can be the same for all PCI boards in the system
if it is set to 0.
Note: The PciID parameter is set by the Dialogic
®
System Software and should not be changed by
the user.
Update to PhysicalSlotNumber parameter help topic (Physical property sheet)
The information in the help topic for the PhysicalSlotNumber parameter should read
as follows:
Description: For a PCI board, specifies the board’s rotary-switch setting. The rotary-switch setting
for Dialogic
®
DM3 PCI boards can be the same for all boards in the system if the value is set to 0.
For a CompactPCI board, specifies the number of the physical slot in which the board is installed.
A value of 1 indicates the first slot in the chassis. (The chassis slot numbers are usually marked on
the front of the chassis.)
Settings: For a PCI board, 0 to 15.
For a CompactPCI board, a positive integer or hexadecimal value.
Note: This parameter is read-only and cannot be modified through the DCM.