User`s guide

Dialogic
®
System Release 6.0 PCI for Windows
®
Release Update, Rev 62 — January 30, 2008 360
Dialogic Corporation
Update to SCbus Clock Rate (User Defined) parameter help topic
The help topic for the SCbus Clock Rate (User Defined) parameter should read as
follows:
Description: If the bus is running in SCbus mode (the TDM Bus Type parameter is set to SCbus),
this parameter determines the clock rate for the SCbus.
Update for UK country parameter file (PTR# 25019)
The UK country parameter file for the Dialogic
®
D/120JCT-LS Board (uk_120j.prm) is
missing from the release. If the board is configured for use in the United Kingdom
(DCM Country parameter is set to United Kingdom), the system will start, but the
system event log will report the following error:
Error downloading file. The uk_120j.prm file cannot be found.
To correct this problem, locate the file eu_120j.prm in the Program Files\Dialogic\data
directory and rename this file to uk_120J.prm.
3.3.3 Dialogic
®
System Software Diagnostics Guide
Update for Remote Diagnostics Package
A remote diagnostics package is now available that allows you to run Dialogic
®
diagnostics utilities remotely from a central site. For further information, see
Section 1.10, “Remote Diagnostics Package”, on page 67 of this Release Update.
Updates to Chapter 20, ISDN Trace Reference
Because of a new feature in the Service Update, the ISDNtrace tool has been
enhanced to include support for DPNSS tracing. For more information about this
feature, see Section 1.29, “Enhanced ISDN Trace Functionality for DPNSS Tracing”,
on page 96 of this Release Update.
Because of a new feature in the Service Update, the ISDNtrace tool has been
enhanced to include new command line options to set the output log file size and to
create multiple backup log files to be archived. For more information about this
feature, see Section 1.16, “File Management Enhancements for ISDNtrace Tool”, on
page 74.
Update to Chapter 21, Telecom Subsystem Summary Tool Reference
Because of an enhancement in the Service Update, the its_sysinfo.htm file now
includes a Windows
®
Package Info section at the beginning of the file. For further
information about this feature, see Section 1.61, “Telecom Subsystem Summary Tool
(its_sysinfo)”, on page 234 of this Release Update.
Update to Chapter 24, PDK Trace Reference
Because of a new feature in the Service Update, PDK Trace supports
CAS/R2MF/Tone tracing and readable log files. A new option for enhanced tracing for
Settings Value Explanation
Default The value of this parameter is to be determined by the system software. Its
current value is indicated by the Resolved.
2MHz Not currently supported.
4MHz The SCbus operates at 4 MHz.
8MHz Not currently supported.