Chapter 11 Configuring Security Features 48
supply a set logins command that specifies the following:
set logins range=range login=off passwd=off
Example:
set logins range=1-2 login=off passwd=off
Procedure for Changing a Users Access Requirements
To configure a user so that he or she does not have to specify a password
when accessing an inbound port, supply a set user command that specifies
the following:
set user name=name password=off
where name is a name to identify the user
Example:
set user name=user1 password=off
Controlling Access to Outbound Ports
This section describes methods for controlling access to outbound serial
ports. An outbound port is one defined on the dev field of the set ports
command for one of the following device types:
prn (used to define printer connections)
mout (used to define outbound modem connections
mio (used to define bi-directional modem connections)
host (used to define host connections)
Default Access
The default for outbound ports is unlimited access.
Restricting Access to Outbound Ports
Use the set auth command to restrict access to outbound ports. See the
description of the set auth command in the Digi One/PortServer TS
Command Reference for more information.
CHAP Authentication for PPP Users
CHAP authentication can be used to restrict PPP user access to outbound
ports. For more information on CHAP configuration, see the set user
command in the device server Command Reference.
Controlling Access to the Command Line
This section describes how to restrict access to the device server
command line.
Method 1 Autoconnection
The autoconnection feature allows you to configure a user to access the