User Manual

86 Chapter 18 Specifications
Device Server EIA 232/422/485 Switch Settings
DB9 Pinouts
WARNING: To prevent electric shock, do not remove the cover of this
module while unit is powered up. There are no user-serviceable parts
inside. Refer servicing to qualified personnel.
CAUTION: This unit has two power inputs. For total isolation from electrical
shock and energy hazard, disconnect both power inputs. The device is
intended to be mounted in an indoor only type system.
Function
Switch Settings
1 2 3 4
EIA-232 Up Down Down Down
EIA-422/485 Full-duplex Down Up Down If up, termination.
If down,
no termination
EIA-485 half-duplex Down Down Up
DB9
Pin
EIA-232
EIA-422/485
Full-Duplex
EIA-485 Half-
Duplex
1 DCD CTS- Not used
2 RxD RxD+ RxD+
3 TxD TxD+ TxD+
4DTR RTS- Not used
5GND GND GND
6 DSR RxD- RxD-
7RTS RTS+ Not used
8 CTS CTS+ Not used
9 NA TxD- TxD-