Specifications

6 DC-530 Operation Manual
2.0 Installation
This section describes the procedure for the installation and setup of the DC-530 counting scale.
2.1 Unpacking
Do not turn scale upside down. Always work with scale on its side! Damage to the load cell can occur if
the scale is turned upside down.
1. Immediately after unpacking, visually inspect the DC-530 counting scale to ensure all components are
included and undamaged. If any were damaged in shipment, notify Rice Lake Weighing Systems and the
shipper immediately.
2. The DC-530 counting scale is carefully packed for protection during shipping. After opening the box,
remove all the components. Check the insides of the box carefully to make sure you have all of the
pieces. The package should include the following:
DC-530 counting scale
Platter support
4 rubber caps
4 screws for platter support
Stainless steel platter
AC power cord
Operation Manual
Warranty card
3. Remove the bag protecting the scale and the protective film covering the front panel and platter.
4. Put the 4 supplied rubber caps on the ends of the platter support.
5. Set the platter support on the scale, lining up the screw holes on the support with the corresponding holes
on the scale. Use the 4 screws supplied to fix the platter support to the scale, taking care not to put strong
pressure down on the platter support while screwing it down to avoid damage to the force balance.
6. Seat the stainless steel platter on the platter supports, making sure that the rubber caps are completely
seated in the corners of the platter.
7. Connect the AC power cord to the plug on the bottom right-hand side of the scale.
8. Store the DC-530 scale box for possible future use.
2.2 Repacking
If the DC-530 counting scale must be returned for modification, calibration or repair, it must be properly packed
with sufficient cushioning materials. Whenever possible, use the original carton when shipping the DC-530.
Damage caused by improper packaging is not covered by the warranty.