Specifications

Configuration Settings 11
6. To change another SPEC code before exiting, repeat Steps 3 and 4.
If you power off the scale while the saving process in going on, you can clear the entire memory of the
scale! Wait until the scale has returned to the Menu Screen before performing any other functions.
7. After returning to the Normal Weighing Mode, power the scale down completely by using the ON/OFF
rocker switch on the bottom of the scale to complete the registering of the changes.
SPEC No Bit 3 Bit 2 Bit 1 Bit 0
00
01 Set Point Operation
00: No Operation [DEFAULT]
01: Common Setpoint
10: Item Setpoint
11: Not Used
LAN
[not currently used - for
future expansion]
0: Disable [DEFAULT]
1: Enable
02 Buzzer Output Type
0: Proper [DEFAULT]
1: Scare/Over
Setpoint Selection
0: Pieces [DEFAULT]
1: Weight
Setpoint Buzzer Output
0: No
1: Yes [DEFAULT]
Setpoint Range
0: Negative
1: Positive [DEFAULT]
03
RS232B for
Printer
Printer Model
00: No Connection [DEFAULT]
01:DIGI TVP1000/ Zebra LP2824
10: EPSON CTM290/TM-U295/TM-U220
11: FL-2
04
RS232A for
Scanner
Connection Type
00: No Connection [DEFAULT]
01: Barcode Scanner
05
RS232C for PC
Connection Type
00: No Connection [DEFAULT]
01: PC
06
RS232C Output
Output Protocol
00: No Output
01: Continuous (this affects the printer output)
10: Manual [by key press] Key [DEFAULT]
11: Not Used
Header Type
NOTE: The header type SPEC only affects output
to a PC, not communication to a printer.
00: No Header
01: Code [DEFAULT]
10: Title
11: Not Used
07
RS232C1 Force
Balance
Baud Rate
000: 19200
001: 9600
010: 4800 [DEFAULT]
011: 2400
100: 1200
08
RS232C1 Force
Balance
Parity
00: Even [DEFAULT]
01: Odd
10: None
11: None
Stop Bit
0: 1 [DEFAULT]
1: 2
Data Length
0: 7 [DEFAULT]
1: 8
Table 3-1. DC-530 Customer Specifications
#AUTION