3.3.6 ALARM CFG
In this window you may enable the digital inputs, the relevant messages associated to it and the relevant
management in case of main power supply lack.
Input1 Mode and Input2 Mode: activation and deactivation of the two digital inputs.
Disabled
Disabled input. Any change of status on the input will not be
handled by the camera.
Rising Edge
Enabled input. The Vega Wireless Camera will start
managing the alarm event as soon as the input turns from the
falling to the rising edge.
Falling Edge
Enabled input. The Vega Wireless Camera will start
managing the alarm event as soon as the input turns from the
rising to the falling edge.
Alarm Message1 and Alarm Message2: defines the text associated to the input 1 and the input 2. The text
can be maximum 30 characters long.
Sms Main Power On: enables the sending of a SMS message (with the Vega Wireless Camera GPRS)
each time the camera is turned on or the power supply is re-established after a blackout. The SMS
message will be sent to the phone numbers inserted in the SMS Number item to be found in the
GPRS configuration page.
Main Power On Message: defines the text of the message sent if the Sms Main Power On item is enabled.
The text can be maximum 30 characters long. The default message is PWR ON.