Warranty

8 www.dimplex.com
Site Selection
Review and consider all of the fol-
lowing conditions for installation:
Dimensions of the unit: 50
5
/
16
"
(128cm) x 19½"(49.5cm)
Unit requires a minimum of two
wall studs in order to ensure a
secure installation
Three possible installation meth-
ods:
Surface mount (pg. 12); In-wall
Recessed (pg. 13); or Flush
mount (pg. 15)
Hardwired or plug-in method
CAUTION: Ensure installation
does not allow replace to be in
direct contact with building vapor
barrier or insulation and meets all
local building code.
!
NOTE 1: A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not essen-
tial in all cases. A dedicated circuit
will be required if, after installa-
tion, the circuit breaker trips or
fuse blows on a regular basis
when the heater is operating. Ad-
ditional appliances on the same
circuit may exceed the current
rating of the circuit breaker.
WARNING: Ensure the power
cord is not installed so that it is
pinched or against a sharp edge
Fireplace Installation
and ensure that the power cord
is stored or secured to avoid
tripping or snagging to reduce
the risk of re, electric shock or
injury to persons.
Construction and electrical
outlet wiring must comply
with local building codes and
other applicable regulations to
reduce the risk of re, electric
shock and injury to persons.
WARNING: To reduce the risk
of re, do not store or use gaso-
line or other ammable vapors or
liquids in the vicinity of the heater.
1. Select a location that is not
susceptible to moisture and
is away from drapes, furniture
and high trafc.
2. For ease of electrical hook up
you may wish to locate the
replace near an existing outlet
(for plug-in convenience) (refer
to NOTE 1).
3. Remove replace, front glass
and hardware from box and
remove all packaging materials
before installation.
4. Store the replace in a safe,
dry and dust free location until
you are ready to install the
replace.