Technical data

Installation
A Class HP Installation and User Instructions R02583-2 09/13
Page 18
Figure 10: Zone connection
5.8.4 Digital Inputs & Temperature
Sensors
The water module contains 5 optional digital
inputs, 4 optional NTC zone temperature sensor
inputs and 1 domestic hot water (DHW) NTC
sensor.
DHW NTC is pre-wired and fitted to the
cylinder. This sensor allows the user
interface to display the actual cylinder
temperature.
NTC zone sensors allow the user interface
to display room temperature in up to 4
different zones and actuate the
corresponding controls accordingly.
Digital input 1 is a spare connection.
Digital input 2 is pre-wired and
enables/inhibits remote control.
Digital inputs 3, 4 & 5 accept room
thermostat connections (volt free) that can
be used to control ambient temperature at
each zone.
Note: The DI’s are volt free and under no
circumstances should 240V be connected
to these, as irreparable damage would
result and void the warranty.