Owner’s Manual Model CFP3913 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this fireplace. For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage.
Table of Contents Welcome & Congratulations. . . . . . . . . . . . . . . . . 3 Important Instructions . . . . . . . . . . . . . . . 4 Fireplace Installation . . . . . . . . . . . . . . . . . . . . . . . 7 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Replacement Parts. . . . . . . . . . . . . . . . . . . . . . . .
Welcome & Congratulations Thank you and congratulations for choosing to purchase an electric fireplace from Dimplex, the world leader in electric fireplaces. Please carefully read and save these instructions. CAUTION: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and will void the warranty.
Important Instructions ① Read all instructions before using this appliance. ② The heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. The trim around the heater outlet becomes hot during heater operation. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9 m) from the front of the unit. CAUTION: High temperature, keep electrical cords, drapery, and other furnishings at least three (3) feet (0.
Important Instructions ⑫ All electrical heaters have hot and arching or sparking parts inside. Do not use in areas where gasoline, paint, or flammable liquids are used or stored or where the unit will be exposed to flammable vapors. ⑬ Do not modify the fireplace. Use it only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
Important Instructions ! NOTE: This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Fireplace Installation ! NOTE: A 15 Amp, 120 Volt alternating current (VAC) circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker.
Operation Three switches provide a choice of heat settings. A switch is in the ON position when the side with the markings on (i.e. I, II, or II) is pushed in. (Figure 1) Switch 1 (I) Manual mode: Controls the electricity supply to the heater and flame manually. (II)Remote mode: Allows the control of electricity supply to the heater and flame through the use of the supplied remote control. ! NOTE: This switch must be in either (I) or (II) to operate with or without heat.
Maintenance Warning: Always disconnect from the power supply before attempting any maintenance. Bulb Replacement The bulbs are located behind the back panel. To gain access to the bulbs: 1. Remove the silver screw that secures the access panel to the firebox as indicated in Figure 2. 2. Remove and slide out panel. 3. Remove the defective lamp by unscrewing it as shown in Figure 3. 4. Replace with a 60 Watt E12 clear chandelier or candelabra. Take care not to over-tighten the bulb. 5.
Maintenance Figure 2 Firebox Mounting Screws (2) Access Panel Screw Firebox Mounting Screws (3) Figure 3 10 Bulbs www.dimplex.
Warranty Products to which this limited warranty applies What this limited warranty covers and for how long This limited warranty applies to newly purchased Electralog fireplace surrounds (mantels) and trims. This limited warranty applies only to purchases made in any province of Canada except for Yukon Territory, Nunavut, or Northwest Territories or in any of the 50 States of the USA (and the District of Columbia) except for Hawaii and Alaska.
Warranty under this limited warranty Defects must be brought to the attention of Electralog Technical Service by contacting Electralog at 1-888-346-7539, or 1367 Industrial Road, Cambridge Ontario, Canada N1R 7G8. Please have proof of purchase, catalogue/model and serial numbers available when calling. Limited warranty service requires a proof of purchase of the product.
Warranty EXEMPLARY, CONSEQUENTIAL, OR INCIDENTAL LOSS, COST, OR DAMAGE ARISING OUT OF OR IN CONNECTION WITH THE SALE, MAINTENANCE, USE, OR INABILITY TO USE THE PRODUCT, EVEN IF Electralog OR ITS directors, officers, or AGENTS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES, COSTS OR DAMAGES, OR IF SUCH LOSSES, COSTS, OR DAMAGES ARE FORESEEABLE.
Replacement Parts Log Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0439290100RP Flicker Motor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000210100RP Flicker Rod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5901110100RP Heater Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2200491000RP Cutout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .