Owner’s Manual Model VF5452L VF2927L IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this fireplace. For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage. To view the full line of Dimplex products, please visit www.dimplex.
Table of Contents Welcome & Congratulations. . . . . . . . . . . . . . . . . . . 3 IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . 4 Fireplace Installation . . . . . . . . . . . . . . . . . . . . . . . . 6 Locating the Firebox. . . . . . . . . . . . . . . . . . . . . . . . . 6 Hardwire Installation. . . . . . . . . . . . . . . . . . . . . . . . . 6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Warranty.
Welcome & Congratulations Thank you and congratulations for choosing to purchase an electric fireplace from Dimplex, the world leader in electric fireplaces. Please carefully read and save these instructions. CAUTION: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and will void the warranty.
IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. The appliance shall not be exposed to dripping or splashing and that no objects filled with liquid, such as vases, shall be placed on the apparatus.
IMPORTANT SAFETY INSTRUCTIONS aged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 17. If the appliance is damaged, check immediately with the supplier before installation and operation. 18. Do not operate any unit with a damaged cord or plug, or if the electric fireplace has been dropped or damaged in any manner, contact Dimplex Technical Service at 1-888-346-7539. 19.
Fireplace Installation WARNING: ANY INSTALLATION AND SERVICE WORK CAN ONLY BE PERFORMED BY QUALIFIED AND AUTHORIZED PERSONNEL. ALL INSTALLATIONS MUST COMPLY WITH ALL LOCAL CODES AND BYLAWS, AND INSPECTED AND APPROVED FOR OPERATION BY LOCAL GOVERNING AUTHORITY PRIOR TO USE. WARNING: Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electric shock and injury to persons.
Fireplace Installation recommended dimensions located in Figure 1. ! NOTE: Dimensions provided are minimum clearances and will vary depending on type of support framing and finishing options. ! NOTE: Framing should be constructed to support: VF2927L - 63 lbs (29 kg) VF5452L - 116 lbs (52 kg) 2. Allow up to 4 ft. (121.9 cm) of service cable for connecting a power supply wire to the cable clamp on fireplace when installing before finishing wall.
Fireplace Installation num conductors. ! NOTE: It is recommended that all drywall installation and finishing be completed after unit is fully installed. 3. In the upper left hand corner of the unit, loosen the two securing screws and remove the electrical cover panel. (Figure 2) 4. Install a 3/8 in. (10 mm) or 1/2 in. (13 mm) cable connector, not included, suitable for mounting in a 7/8 in. (22 mm) hole, to the cable plate and feed the supply cable through the connector and secure. 5.
Fireplace Installation to the back plate. CAUTION: Ensure the wire connectors are securely tightened, so no bare wires (live or neutral) are exposed. 10. Ensure the grounding wire of the supply cable is securely attached to the grounding screw. ! NOTE: The wire connections on the firebox feed into a 3-prong plug just below the electrical cavity opening, before closing the electrical cover ensure that the plug is fully installed. 11. Reinstall the electrical cover panel. 12.
Operation Figure 2 A B C D E F IR Remote Sensor WARNING: This electric firebox must be properly installed before it is used. The power switch (Figure 2A) must first be switched "I" to operate the appliance. An ‘Opti-V’ logo will appear on the screen for about 3 seconds before the flame picture starts . ! NOTE: The user may notice a blank screen for approximately 5 seconds, every 30 minutes. This is normal and should not be a cause for concern.
Operation button brightens the screen. ! NOTE: On the VF5452L there are brightness controls for each LED screen. The brightness controls for the right screen are located in the center of the unit. Figure 3 Volume Controls Battery Cover Remote Control Operation The remote control may be operated once the appliance is switched to the ON "I" position (Figure 2A). Aim the remote control at the IR remote sensor located on the left of the fire display (Figure 2).
Maintenance WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. Glass Cleaning Servicing Except for installation and cleaning described in this manual, an authorized service representative should perform any other servicing. The glass is cleaned in the factory during the assembly operation. During shipment, installation, handling, etc.
Warranty Two Year Limited Warranty Products to which this limited warranty applies This limited warranty applies to the following models of your newly purchased Dimplex electric fireplace VF5452L and VF2927L and to newly purchased Dimplex fireplace surrounds (mantels) and trims.
Warranty • • • • 14 Dimplex will in its sole discretion either repair or replace such defective product or part without charge. If Dimplex is unable to repair or replace such product or part, or if repair or replacement is not commercially practicable or cannot be timely made, Dimplex may, in lieu of repair or replacement, choose to refund the purchase price for such product or part.
Replacement Parts LED Light Strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9600880100RP LED Light Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9600930100RP Opti-V Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9600950100RP Power Supply Wire Harness. . . . . . . . . . . . . . . . . . . . . . . . . . . 9600980100RP Electrical Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .