2
Physical Specifications
Physical Specifications
Tab le 2 Physical Specifications
Type Specification Comments
Weight 14.5 kg (32 lbs)
Dimensions
(height × width × depth)
180 x 345 x 435 mm
(7.0 x 13.5 x 17 inches)
Line voltage 100 – 240 VAC, ± 10% Wide-ranging capability
Line frequency 50 or 60 Hz, ± 5%
Power consumption 180 VA, 110W / 375 BTU
Ambient operating
temperature
4–55 °C (41–131 °F)
Ambient non-operating
temperature
-40–70 °C (-4–158 °F)
Humidity < 95%, at 25–40 °C (77–104 °F) Non-condensing
Operating altitude Up to 2000 m (6562 ft)
Non-operating altitude Up to 4600 m (15091 ft) For storing the module
Safety standards: IEC, CSA,
UL