Storage
1. Wait for the engine to cool, then clean the engine with a
clean cloth.
2. When the generator is to be stored for longer than 20
days, prepare the engine for storage by emptying the fuel
tank and draining all fuel lines (see Figure 8). Clean out
area around spark plug and remove. Pour one tablespoon
of engine oil into the cylinder through the spark plug hole.
Reinstall the spark plug, but leave the spark plug wire
disconnected. Pull recoil starter handle to distribute oil in
the cylinder. Stop after one or two revolutions when you
feel the piston start the compression stroke (when you start
to feel resistance).
3. Apply a thin coat of rust preventive oil to all uncoated
metal parts.
4. Cover and store in a dry, well-ventilated 4. area out of reach
of children.
19
Figure 8
AIR FILTER
ASSEMBLY
CYLINDER
ASSEMBLY
DRAIN
PLUG