CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 1 CF-60 AC CF-50 ACDZ CF-50 AC CF-40 AC CF-18 CF-25 CF-35 AC CF-18,CF-25,CF-35, CF-40, CF-50, CF-50DZ, CF-60 AUS Compressor Cooler Instruction Manual M_81003
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 3 CoolFreeze Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is handed over to another person, this operating manual must be handed over along with the device. Contents 1 2 3 4 5 6 7 8 9 10 11 Notes on using the manual ...................................................... 7 Safety instructions ........................................................................
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 4 CoolFreeze 1 1 2 4 3 2 1 CF-25, CF-35, CF-40, 3 1 2 3 4 TEMPERATURE BATTERY MONITOR ERROR POWER HIGH 0 LOW COLD FREEZE 12/24V DC CF-18 4 5
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 5 CoolFreeze 4 1 2 3 4 5 6 7 POWER ON OFF ° SET UP DOWN + – ERROR CF-25, CF-35, CF-40, CF-50, CF-60 5 4 1 12/24V DC 6 1 2 4 100-240V~AC 3 12/24V DC EMERGENCY OVERRIDE FUSE NORMAL USE CF-35, CF-40, CF-50, CF-60 CF-25 7 2 1 1 CF-35, CF-40, CF-50, CF-60 5
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 6 CoolFreeze 8 A B CF-50, CF-60 9 1 2 3 4 5 6 6 10 1 2
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 7 Notes on using the manual 1 CoolFreeze Notes on using the manual The following symbols are used in this operating manual: Caution! Safety instruction: Failure to observe this instruction can cause personal injury or damage the device. Caution! Safety instruction: relating to a danger from an electrical current or voltage. Failure to observe this instruction can cause injury or damage the device and impair its function.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM CoolFreeze 2.1 Page 8 Safety Instructions General safety • Caution – Danger of electrocution! • • • • • • – When using the device on boats: If the device is powered by the mains, ensure that the power supply is protected with a ground fault interrupter circuit. Check that the voltage specification on the type plate corresponds to that of the energy supply. Only connect the device as follows: – With the cable supplied (Fig.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Intended use 2.2 Page 9 CoolFreeze Operating the device safely • Caution – Danger of electrocution! • • • • • Do not touch exposed cables with your bare hands. This especially applies when operating the device from an AC mains. Before starting the device, ensure that the power supply line and the plug are dry. Do not place any electrical devices inside the cooler. Set up the device in a dry location where it is protected against splashing water.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 10 CoolFreeze 3 Function description Scope of delivery Fig. 1 page 4, shows the scope of delivery.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 11 CoolFreeze Operation 5 Function description The cooler can chill products, keep them cool as well as freeze them. A low maintenance, CFC-free refrigerant circuit with compressor provides the cooling. The extra strong CFC-free insulation and powerful compressor ensure especially fast cooling.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 12 CoolFreeze 5.1 Operation Operating and display elements CF-25, CF-35, CF-40 Lock for lid: Fig. 2 1, page 4. CF-18 Operating panel and connection socket (Fig.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 13 CoolFreeze Operation CF-25, CF-35, CF-40, CF-50, CF-60 Operating panel (Fig.
CF18-60_M_81003:PowerVac_PV-100 CoolFreeze 5.2 3/9/08 3:53 PM Page 14 Operation Accessories If you want to operate the coolers CF-18 and CF-25 from the 240 V AC mains, be sure to use the rectifier WAECO CoolPower EPS-816 (CF-18 only) or EPS-817 (CF-18 and CF-25). 6 Operation 6.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 15 CoolFreeze Operation Selecting the temperature units – ºC or ºF CF-25, CF-35, CF-40, CF-50, CF-60 You can switch the temperature display between Celsius and Fahrenheit. This is how to do it: ➤ Switch on the cooler. ➤ Press the “SET” button (Fig. 4 4, page 5) twice. ➤ Use the “UP +” (Fig. 4 6, page 5) and “DOWN -” (Fig. 4 7, page 5) buttons to select Celsius or Fahrenheit.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 16 CoolFreeze 6.3 Operation Connecting the cooler Connecting to a battery (Vehicle or boat) The cooler can be operated with 12 V or 24 V DC. Caution – Danger of damaging the device! Disconnect the cooler and other consumer units from the battery before you connect the battery to a quick charging device. Overvoltage can damage the electronics of the device.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 17 CoolFreeze Operation CF-18, CF-25 To operate the coolers CF-18 and CF-25 from the 220–240 V AC mains, use the optional accessory rectifier WAECO CoolPower EPS-816 (CF-18 only) or EPS-817 (CF-18 and CF-25). 6.4 Using the battery monitor The device is equipped with a multi-level battery monitor that protects your vehicle battery against excessive discharging when the device is connected to the on-board 12/24 V supply.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 18 CoolFreeze Troubleshooting CF-25, CF-35, CF-40, CF-50, CF-60 ➤ Switch on the cooler. ➤ Press the “SET” button (Fig. 4 4, page 5) three times. ➤ Use the “UP +” (Fig. 4 6, page 5) and “DOWN -” (Fig. 4 7, page 5) buttons to select the battery monitor mode. ➤ Digital display will be as follows. (LOW) ✔ (MED) (HIGH) The selected mode then appears in the display for a few seconds.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 19 Technical Data CoolFreeze CF-18 ➤ ✔ ✔ ✔ Slide the sliding switch (Fig. 3 4, page 4) to “LOW” or “HIGH” battery protection (See 6.4 “using the battery monitor” for suitable level). The “POWER” LED is lit green. The cooler starts cooling the interior. When the cooling temperature has been reached, the “POWER” LED is lit amber. CF-25, CF-35, CF-40, CF-50, CF-60 ➤ Press the “ON/OFF” button (Fig.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 20 CoolFreeze 6.6 Setting the temperature CF-18 ➤ Set the cooling temperature with the temperature controller (Fig. 3 1, page 4). CF-25, CF-35, CF-40, CF-50, CF-60 ➤ Press the “SET” button (Fig. 4 4, page 5) once. ➤ Use the “UP +” (Fig. 4 6, page 5) and “DOWN -” (Fig. 4 7, page 5) buttons to select the cooling temperature. ✔ The cooling temperature appears in the display for a few seconds.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 21 CoolFreeze ➤ ➤ ➤ ➤ ➤ 6.10 Take out the contents of the cooling device. If necessary, place them in another cooling device to keep them cool. Switch off the device. Leave the cover open. Wipe off the defrosted water. Replacing the device fuse (240V) Only CF-35, CF-40, CF-50, CF-60 Caution – Danger of electrocution! Disconnect the connection cable before you replace the device fuse. ➤ ➤ ➤ ➤ 6.11 Pull off the connection cable.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 22 CoolFreeze 6.12 Replacing the light bulb Only CF-25, CF-35, CF-40, CF-50, CF-60 ➤ Press the switch pin (Fig. 10 2, page 6) downwards so that the transparent part (Fig. 10 1, page 6) of the lamp can be removed at the front. ➤ Replace the light bulb ensuring that: i) the LED’s inside the bulb face toward the transparent cover ii) the polarity is correct. Test for operation and if the new bulb does not work fit it the other way around.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 23 CoolFreeze 9 Troubleshooting Fault Possible cause Suggested remedy Device does not function, Power LED does not glow. There is no voltage present in the 12/24 V socket (cigarette lighter) in your vehicle. No voltage present in the AC voltage socket. The device fuse is defective. The integrated mains adapter is defective. Defective component. The ignition must be switched on in most vehicles to apply current to the cigarette lighter.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 24 CoolFreeze 10 Disposal ➤ Place the packaging material in the appropriate recycling waste bins wherever possible. If you wish to finally dispose of the device, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 25 CoolFreeze Test/certificates: – 73/23/EEC – Low Voltage Electrical Equipment Directive – 89/336/EEC – EMC Directive – 95/54/EEC Versions and delivery options may vary due to technical modifications. This device is CFC-free. The coolant circuit contains R134a.
CF18-60_M_81003:PowerVac_PV-100 CoolFreeze 26 3/9/08 3:53 PM Page 26
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 27 CoolFreeze 27
CF18-60_M_81003:PowerVac_PV-100 3/9/08 3:53 PM Page 28 CoolFreeze World Headquarters D WAECO International GmbH · Hollefeldstraße 63 · D-48282 Emsdetten phone: +49 2572 879-195 fax: +49 2572 879-322 e-mail: info@waeco.de AUS WAECO Pacific Pty. Ltd. 1 John Duncan Court Varsity Lakes QLD 4227 phone: +61 7 55076000 fax: +61 7 55076001 e-mail: sales@waeco.com.au N WAECO Norge AS Leif Weldingsvei 16 N-3208 Sandefjord phone: +47 33428450 fax: +47 33428459 e-mail: firmapost@waeco.