CFX-28-CFX-65--B-EN-AUSv1.book Seite 1 Montag, 14.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 2 Montag, 14.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 3 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is passed on to another person, this operating manual must be handed over to the user along with it. The manufacturer cannot be held liable for damage resulting from improper usage or incorrect operation. Contents 1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . .
CFX-28-CFX-65--B-EN-AUSv1.book Seite 4 Montag, 14. November 2016 10:53 10 Explanation of symbols CFX28 – CFX100W 8 Cleaning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 9 Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 10 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 11 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . .
CFX-28-CFX-65--B-EN-AUSv1.book Seite 5 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W 2 Safety instructions 2.1 General safety ! WARNING! Safety instructions • Do not operate the device if it is visibly damaged. • If this device's power cable is damaged, it must be replaced by the manufacturer, customer service or a similarly qualified person in order to prevent safety hazards. • This device may only be repaired by qualified personnel. Improper repairs can lead to considerable hazards.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 6 Montag, 14. November 2016 10:53 10 Safety instructions CFX28 – CFX100W • Only connect the device as follows: – With the DC cable to a DC plug socket in the vehicle (e. g. cigarette lighter) – Or with the AC connection cable to the AC mains supply • Never pull the plug out of the socket by the cable. • If the cooler is connected to the DC socket: Disconnect the cooler and other power consuming devices from the battery before connecting the quick charging device.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 7 Montag, 14.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 8 Montag, 14. November 2016 10:53 10 Accessories 4 CFX28 – CFX100W Accessories Available as accessory (not included in scope of delivery): Designation Item no.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 9 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W 6 Function description Function description The cooler can chill products, keep them cool as well as freeze them. A low maintenance refrigerant circuit with compressor provides the cooling. The generous insulation and powerful compressor ensure efficient and fast cooling. The cooler is portable. The cooler can withstand a heel (inclination) of 30°, for example when used on boats. 6.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 10 Montag, 14. November 2016 10:53 10 Function description 6.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 11 Montag, 14.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 12 Montag, 14.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 13 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W Operation 7 Operation 7.1 Before initial use I NOTE Before starting your new cooler for the first time, you should clean it inside and outside with a damp cloth for hygienic reasons (please also refer to the chapter “Cleaning and maintenance” on page 27).
CFX-28-CFX-65--B-EN-AUSv1.book Seite 14 Montag, 14. November 2016 10:53 10 Operation CFX28 – CFX100W ➤ Re-fit hinges in new positions. ➤ Insert the lid in the hinges on the opposite side (C) (CFX50W, CFX65W, CFX65DZ only). Additionally the centre hinge has to be changed (CFX100W only): 6 D C E B A CFX100W ➤ Remove two plastic covers from the centre hinge (A). ➤ Remove four screws from the centre hinge (B) and take off the hinge.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 15 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W Operation Selecting the temperature units Temperature display units can be switched between Celsius and Fahrenheit as follows: ➤ Switch on the cooler. ➤ Press the “SET” button (fig. 3 4, page 11) twice. ➤ Use the “UP +” (fig. 3 7, page 11) or “DOWN –” (fig. 3 6, page 11) buttons to select Celsius or Fahrenheit. ✓ The selected temperature units then appear in the display for a few seconds.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 16 Montag, 14. November 2016 10:53 10 Operation 7.3 CFX28 – CFX100W Connecting the cooler Connecting to a battery (Vehicle or boat) The cooler can be operated with 12 V or 24 Vg. A NOTICE! Danger of damage! Disconnect the cooler and other consumer units from the battery before you connect the battery to a quick charging device. Overvoltage can damage the electronics of the device.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 17 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W 7.4 Operation Using the battery monitor The device is equipped with a multi-level battery monitor that protects your vehicle battery against excessive discharging when the device is connected to the on-board 12/24 V supply. If the cooler is operated when the vehicle ignition is switched off, the cooler switches off automatically as soon as the supply voltage falls below a set level.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 18 Montag, 14. November 2016 10:53 10 Operation 7.5 A CFX28 – CFX100W Using the cooler NOTICE! Danger of overheating! Ensure at all times that there is sufficient ventilation so that the heat that generated during operation can dissipate. Ensure that the ventilation slots are not covered. Make sure that the device is sufficiently far away from walls and other objects so that the air can circulate. ➤ Place the cooler on a firm foundation.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 19 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W Operation 7 1 CFX50W, CFX65W 8 1 2 CFX65DZ ! EN CAUTION! Health hazard! CFX65DZ: If the temperature in the freezer compartment (fig. 8 1, page 19) is very low (–22 °C), the temperature range in the cooling department (fig. 8 2, page 19) can be below freezing as well.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 20 Montag, 14. November 2016 10:53 10 Operation CFX28 – CFX100W I NOTE Displayed temperature • CFX28, CFX35W, CFX40W, CFX50W, CFX65W, CFX100W: The temperature displayed is that of the large interior compartment (e.g. CFX50W, CFX65W: fig. 7 1, page 19). • CFX65DZ: – With fridge/freezer divider in: The temperature displayed is that of the freezer compartment (fig. 8 1, page 19).
CFX-28-CFX-65--B-EN-AUSv1.book Seite 21 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W 7.7 Operation Enabling WiFi signal for optional app (all except CFX28 and CFX65DZ) The cooler can be controlled via WiFi using an app that you can install on a compatible device. The app has control, display and alarm functions. For further information go to the Dometic website for your country (see back page). Note that the app may not be available in your country.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 22 Montag, 14. November 2016 10:53 10 Operation 7.8 CFX28 – CFX100W Set brightness of display The display brightness can be dimmed for low ambient light conditions. To set the dimming level of the display proceed as follows: ➤ Switch on the cooler. ➤ Press the “SET” button (fig. 3 4, page 11) four times. ➤ Use the “UP +” (fig. 3 7, page 11) or “DOWN –” (fig. 3 6, page 11) buttons to set the brightness of the display.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 23 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W 7.10 Operation USB port for power supply USB port allows you to charge small devices like mobile phones and mp3-players. To use your cooling box with any USB devices, simply connect a USB cable (not included) to your device. I NOTE Ensure that any small device connected to the USB port is compatible with 5 V/500 mA operation. 7.11 Switching off the cooler ➤ Empty the cooler. ➤ Switch the cooler off.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 24 Montag, 14. November 2016 10:53 10 Operation 7.12 CFX28 – CFX100W Defrosting the cooler Humidity can form frost in the interior of the cooling device or on the evaporator. This reduces the cooling capacity. Defrost the device in good time to avoid this. A NOTICE! Danger of damage! Never use hard or pointed tools to remove ice or to loosen objects which have frozen in place.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 25 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W 7.14 Operation Replacing the plug fuse (12/24 V) 9 1 2 3 ➤ Unscrew the contact pin housing (3) from the plug (1). ➤ Replace the defective fuse (2) with a new fuse that has the same rating (3AG, 15 A). ➤ Re-assemble the plug in reverse order.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 26 Montag, 14. November 2016 10:53 10 Operation 7.15 CFX28 – CFX100W Replacing the light PCB 0 1. + – ° SET 2. 3. ➤ Disconnect the power supply to the device. ➤ Pry out the transparent cover with a screwdriver (1). ➤ Unscrew the PCB mounting screws (2). ➤ Pull out the plug from the PCB (3). ➤ Replace the defective light PCB with a new one. ➤ Fit new PCB using reverse of removal instructions. ➤ Press the transparent cover back into the housing.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 27 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W 8 ! A Cleaning and maintenance Cleaning and maintenance WARNING! Always disconnect the device from the power supply before you clean and service it. NOTICE! Risk of damage • Never clean the cooler under running water or in dish water. • Do not use abrasive cleaning agents or hard objects during cleaning as these can damage the cooler. ➤ Occasionally clean the device interior and exterior with a damp cloth.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 28 Montag, 14. November 2016 10:53 10 Troubleshooting 10 CFX28 – CFX100W Troubleshooting Fault Possible cause Suggested remedy Device does not function, LED does not glow. There is no voltage The ignition must be switched on in present in the 12/24 V most vehicles to apply current to the socket (cigarette lighter) cigarette lighter. in your vehicle. No voltage present in the AC voltage socket. Try using another plug socket. The device fuse is defective.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 29 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W 11 Disposal Disposal ➤ Place the packaging material in the appropriate recycling waste bins wherever possible. M If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations. 12 Technical data Ref. no.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 30 Montag, 14. November 2016 10:53 10 Technical data Ref. no.: CFX28 – CFX100W CFX50W CFX65W CFX65DZ 9105306497 9105306498 9105306499 12/24 Vg and 100 – 240 Vw Connection voltage: Rated current: 12 Vg: 7.8 A 24 Vg: 3.6 A 12 Vg: 8.2 A 24 Vg: 3.8 A 100 Vw: 0.95 A 100 Vw: 1.0 A 100 Vw: 0.75 A 240 Vw: 0.46 A 240 Vw: 0.48 A 240 Vw: 0.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 31 Montag, 14. November 2016 10:53 10 CFX28 – CFX100W Technical data CFX100W Ref. no.: 9105306556 Connection voltage: 12/24 Vg and 100 – 240 Vw Rated current: 12 Vg: 10.5 A 24 Vg: 5.0 A 100 Vw: 1.25 A 240 Vw: 0.
CFX-28-CFX-65--B-EN-AUSv1.book Seite 32 Montag, 14. November 2016 10:53 10 BENELUX Dometic Branch Office Belgium Zincstraat 3 B-1500 Halle +32 2 3598040 +32 2 3598050 Mail: info@dometic.be BRAZIL Dometic DO Brasil LTDA Avenida Paulista 1754, conj. 111 SP 01310-920 Sao Paulo +55 11 3251 3352 +55 11 3251 3362 Mail: info@dometic.com.br DENMARK Dometic Denmark A/S Nordensvej 15, Taulov DK-7000 Fredericia +45 75585966 +45 75586307 Mail: info@dometic.