Service manual

20
- Make sure that the thermostat can be turned within the entire control
range.
- Adjust the capillary spiral that remains outside of thermostat so that it does
not overhang from the outline of the cabinet.
- Seal the point of exit of capillary from the cabinet with rubber sealing.
- Check electrical insulation resistance according to 2.3.3.
2.3.7 Replacing timer
Paragon-type timer
- Remove timer cover. (Fig. 89)
- Remove wire clamp, push down electrical wire. (Fig. 90)
- Unscrew screws securing timer. (Fig. 91)
- Replace timer, set: turn defrost marking clockwise by 90ยบ compared to
marking on the casing. Meanwhile, you should hear 2 clicks. This way the
timer is definitely turned on. (Fig. 92, 93)
- Reinsert timer, making sure that the rotating part sits in the bore of the
textile-bakelite housing. (Fig. 94)
- Secure timer with screws.
- Push back electrical wires according to the wiring diagram.
- Reinsert timer cover, secure.
- Check electrical insulation resistance according to 2.3.3.
Figure 89 Figure 90 Figure 91
Figure 92 Figure 93
Figure 94