SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet Section 1-Chemical Product and Company Identification Product: Lithium lon cell Common name: Lithium battery Model: H18650CH Rating of battery: 3.6V, 2600mAh, 9.36Wh Manufacture: SHEN ZHEN BAK POWER BATTERY CO., LTD. Address: Bak Industrial Park, Kuichong Street, Longgang District, Shenzhen Post Code: 518119 Emergency Telephone: +86-755-61886818 Fax No.: +86-755-89770447 E-mail: info@bak.com.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet This product is an article which contains a chemical substance. Safety information is given for exposure to the article as sold. Intended use of the product should not result in exposure to the chemical substance. This is a battery. In case of rupture: the above hazards exist.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet No information available. (d) Unknown Toxicity 10% of the mixture consists of ingredient(s) of unknown toxicity. (e) Other information No information available. (f) Interactions with Other Chemicals No information available. Section 3- Composition/Information on Ingredient Chemical Name Molecular formula CAS No. Weight (%) lithium manganese(iii,iv) oxide LiMn2O4 12057-17-9 38.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet Eyes touch: Rinse immediately with plenty of water for at least 15 mins. Contact a doctor if symptoms persist. Inhalation: Remove from exposure site to fresh air. Keep at rest. Obtain medical attention. Ingestion: Rinse mouth out with water. Seek medical advice immediately.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet clear out hazardous gases. The preferred response is to leave the area and allow the vapors to dissipate. Avoid skin and eyes contact or inhalation of vapors. Remove spilled liquid with absorbent and incinerated. If leakage of the battery happens, liquid could be absorbed wit sand, earth or other inert substance and contaminated area should be ventilated meantime.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet fire. Avoid storage in direct sunlight. Do not store together with oxidizing and acidic materials. Section 8- Exposure Controls, Personal Protection (a)Control parameters Exposure Guidelines Chemical Name ACGIH TLV lithium TWA: 0.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet hand with chemical resistant rubber gloves. If battery is burning, leave the area immediately. In abuse, use NIOSH approved acid gas filter mask or self-contained breathing apparatus. Hand protection: None under normal use. In case of spilling, use PVC, neoprene or nitrile gloves of 15miles (0.015 inch) or thicker. Eye/Face protection: None required under normal conditions.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet Decomposition temperature: Not available Self-igniting: Product is not self igniting. Explosive properties: Risk of explosion by shock, friction, fire or other sources of ignition.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet (e) Incompatible materials Strong oxidizer, strong acid. (f) Hazardous decomposition products Under fire conditions, the electrode materials can form carcinogenic nickel and cobalt oxides. Section 11- Toxicological information (a) Information on the likely routes of exposure Inhalation: Inhalation of a large number of vapors or fumes released due to heat may cause respiratory.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet Reproductive Toxicity: No data available. Chronic Toxicity: No data available. Target Organ Effects: No data available. Aspiration Hazard: No data available. Section 12- Ecological Information Toxicity ·Aquatic toxicity: No further relevant information available. ·Persistence and degradability: No further relevant information available.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet licensed waste carrier. c. The battery should have their terminal insulated in order to prevent short circuits during transportation to the disposal site. Note: Consult your local or region authorities, disposal maybe subject to national, state, or local laws.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.: LCS1601130839S Safety Data Sheet Marine pollutant: No Special precautions for user: Warning: Miscellaneous dangerous substances and articles. Danger code (Kemler): Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code: Not applicable. UN "Model Regulation": UN3480 or UN3481, LITHIUM ION BATTERIES, 9, Section 15- Regulatory information OSHA hazard communication standard (29 CFR 1910.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. REPORT NO.