Product data

For more Information
please call
1-800-Belden1
Description:
22 AWG stranded (7x30) TC conductors, polypropylene insulation, twisted pair, overall Beldfoil shield
(100% coverage), 24 AWG stranded TC drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
1 22 7x30 TC - Tinned Copper
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
PP - Polypropylene 0.254
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil® Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
24 7x32 TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.508
Overall Cable
Overall Nominal Diameter: 3.632 mm
Pair
Pair Color Code Chart:
Number Color
1 Black & Red
Pair Lay Length & Direction:
Lay Length (mm) Twists/ft. (twist/m)
44.449825 22.508
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +60°C
UL Temperature Rating: 60°C
Bulk Cable Weight: 20.835 Kg/Km
Max. Recommended Pulling Tension: 111.205 N
Min. Bend Radius (Install)/Minor Axis: 38.100 mm
Page 1 of 3 02-01-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1266A Multi-Conductor - Single-Pair Cable