dBm to 0 dBm, and the recommended range is from -15 dBm to -5 dBm.
Feedback Signal Connection Error
Alarm message
LCD: FEEDBACK LINK ERROR! Press Any key to Esc
LED_ SysErr: Flashing (during the ADPC process)
Cause: Feedback signal connection is interrupted, or signal level changes dramatically
during the ADPC process.
Solution: Cancel the ADPC function manually and then check the connection and the
level of the feedback signal. Start the ADPC function again after the problem is
resolved.
ADPC Error
Alarm message
LCD: ADPC ERROR! Press Any key to Esc
LED_ SysErr: ON (during ADPC process)
Cause: The ADPC process goes wrong.
Solution: Cancel the ADPC function manually and then check the product status. Start
the ADPC function again after the problem is resolved.
5.3 Other Problems
Temperature
Alarm message
LCD: TEMP HIGH
LED_ SysErr: ON
Cause: The Temperature of the exciter is too high.
Solution: Cool the exciter.
No RF output
Alarm message
LCD: None
LED_ RFON: Off
Cause: RF output can be turned off via front panel or serial port or WEB interface. Or if
the exciter has a breakdown, there would be no RF output too.
Solution: Check the setting of "RF" via front panel, serial port or WEB interface. Restart
the exciter if necessary. If the problem still exists, contact the manufacturer for further
solution.
Note:
If "Slow ON/OFF" function is turned on (user configurable in advanced settings), during
power changing process, LED_RFON may be flashing.