ENIGMA-X SHOWER DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine® reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings, manuals, warranty information or additional details please refer to your model’s web page on DreamLine.com SHDR-61606210-## SHDR-61487610-## SHDR-61607610-## These instructions will show the installation of the shower door. Please follow the same steps for the installation of the tub door.
Preparation 1. Prior to installation, examine all boxes and packages for shipping damage and compare the piece count with your packing slip. After opening all boxes and packages read this introduction carefully. Check that all of the needed parts are included in the package by checking off the components on the “Detailed Diagram of Shower Door Components”.
Tools Tape Measure Level Drill bit (Ø=3/8") (10mm) Painter’s Tape Drill bit (Ø=1/4") (6mm) Caulk Pencil Power Drill Phillips Screwdriver Hammer Drill bit (Ø=5/16") (8mm) Drill bit (Ø=1/8") (3mm) Chop-saw or Hacksaw (with blade for cutting stainless steel) Razor Knife NOTE: Unpack your unit carefully and inspect it. Lay it out and identify all parts using the detailed diagram and packing list in this manual as a reference.
Detailed Diagram ‘A’of Shower Door Components 11 7 10 8 1 12 2 13 4 3 14 15 5 16 17 6 18 9a/9b 19 20 Packing List A PART# 01 02 03 04 05 06 07 08 09a 09b 10 DESCRIPTION Door stopper Stationary glass Upper guide rail Roller Glass door Handle Glass bracket Guide rail bracket Wall anchor Ø 3/8”(10mm) Wall anchor Ø5/16”(8mm) Large Truss Head Screw ST6 x 55 QTY 2pcs 1pc 1pc 2pcs 1pc 1pc 2pcs 2pcs 2pcs 2pcs 2pcs PART # 11 12 13 14 15 16 17 18 19 20 for Model # SHDR-61487610-07/-08 SHDR-6160
Detailed Diagram ‘B’ of Shower Door Components (for 72” model width) 24 21 23 14 25 22 11 19 9b Packing List B Small Stationary Glass (#23) 18 QTY 2pcs 1 each 1pc ST4.
Installation steps 1. Measure the distance between the two finished walls at the top, middle and bottom. This distance is marked as “W”. Also, check the threshold for level and the walls for plumb. Top See Fig 1 for details Note: The minimum threshold requirement for the ENIGMA-X is 2-3/4” of flat threshold space. Middle Bottom 2-3/4” minimum W Fig 1 2. The Upper Guide rail (#03) has been precut for the model width of: 48”, 60” or 72” (the actual rail is shorter than the model width by design).
3. Attach the Upper guide rail (#03) to the Stationary glass (#02) with the Glass brackets (#07) and tighten the bolts into the pre-drilled holes in the Upper guide Rail (#03). Make sure both adjustment disks are installed in the same direction with the high spot towards the door end. (see *Note below) Make sure that the guide rail is attached parallel with the top edge of the glass.
ATTENTION: This step shows the Small Stationary glass bracket (#21) installation for the 72” model only (not included with the 60” model). 4. If the width of your model is 72” and includes the Small Stationary glass (#23), attach the Small Stationary glass bracket (#21) to the Upper guide rail for 72” (#24) between the Door stopper (#01) and the Guide Rail bracket (#08) as shown in Fig. 5. This bracket will be repositioned when the Small Stationary glass (#23), is installed.
6. Place the Stationary glass (#02) with the Upper Guide Rail (#03) onto the threshold and position it against the wall. (Please note that the Stationary Glass (#02) installs on the outside and the Upper guide rail (#03) goes on the inside of the shower) Make sure the Stationary glass (#02) and the Upper guide rail (#03) are leveled. If a horizontal adjustment is required, adjust it by loosening, rotating and re-tightening the disks on the Glass brackets (#07).
ATTENTION: This step shows the Small Stationary Glass (#23) installation for the 72” model only (not included with the 60” model). rotate disk(s) to level rail 7. If installing the 72” model: Unscrew the disk from the Small Stationary glass bracket (#21) and loosen the set screw that secures the bracket to the guide rail. If necessary, slide the Door Stopper (#01) away from the area so that it will not interfere with the placement of the Small Stationary Glass (#23).
8. Once the Upper Guide Rail (#03) is level, mark the position of the Wall bracket (#19) and Guide Rail brackets (#08) on the wall. *NOTE: If installing the 72” model, perform the same procedure on the opposite wall to mark the Wall bracket (#19) for the Small stationary panel glass (#23). (Fig 9.4*) See Fig 9 for details 2 1 inside 3 4* inside 9. Make sure that your Stationary glass (#02) is parallel to the Fig 9 front edge of the threshold and mark it.
10. After marking the positions of all the hardware, set the Stationary glass (#02) with the Upper Guide Rail (#03) aside. (If installing the 72” model, also remove the Small stationary panel glass (#23) from the Upper Guide Rail (#03)). Remove the Guide Rail Brackets (#08) from the Upper Guide Rail (#03) and the Wall bracket (#19) from the Stationary glass (#02). Place the Wall bracket (#19) and Guide Rail Brackets (#08) back to the outlined positions and mark the holes for drilling.
12. Fasten the Wall bracket (#19) to the wall using the ST4.2×55 Truss head screw (#18).(Fig 13.1) Mount the base parts of the Guide Rail brackets (#08) onto both walls using the ST6×55 Large Truss head screw (#10). Note that the adjustment set screws must be aligned vertically for easier access to adjust for level after the glass is installed. See Fig 13 for details 2 1 3 Fig 13 13a. To install Guide Block (#12): Loosen the set screw and remove the guide block face plate (Fig. 14a.
13b. If installing the 72” model, repeat step#13a for the Small Stationary Glass bottom bracket (#22). Loosen the set screw and remove the guide block face plate (Fig. 14b.5) Apply silicone to the underside of the Guide Block (#22) and screw the Guide Block (#22) to the threshold. 1 use a pencil or a center-punch to mark the hole 2 *see note *NOTE: ◾For installation into an acrylic threshold: drill an Ø1/8”(3mm) hole and use the ST4.
14. Reposition the Stationary glass (#02) and Upper Guide rail (#03) onto the threshold and fasten both sleeves of the Guide rail brackets (#08) to the brackets on the walls. Tighten the set screws on the Guide rail brackets (#08) to secure the Upper guide rail (#03). Position the bracket set screws so that they are accessible from the top and bottom. (Fig 15.2 & 15.3) 1 Assemble the Wall bracket (#19) at the bottom corner of the Stationary glass (#02).
. If installing the 72” model, attach the Small stationary panel glass (#23) to the Upper Guide Rail (#03) using the Small Stationary Glass Bracket (#21). Attach the face plate to the Wall Bracket (#19). 1 2 3 4 See Fig 17 for details 5 Fig 17 outside 17. Attach the Guide block face plate to the installed Guide Block (#22) and tighten the set screw with the supplied allen wrench. Use the supplied Decorative caps to cover the screw holes.
18a. For the 48”or 60“ model size: Measure the distance from the edge of the Guide block (#12) to the wall .This distance will be “X”. Cut the Anti-splash threshold (#15) to the size of: X” + 3/8”. See Fig 19a for details for 48”or 60“ model X X + 3/8” Fig 19a 18b. For the 72” model size: Measure the distance between the edge of the Guide block (#12) to the Small Stationary Glass bottom bracket (#22) .This distance will be “L”. Cut the Anti-splash threshold (#15) to the size of: L” + 3/4”.
19. Apply silicone to the bottom of the Anti-Splash Threshold (#15.) Remove the guide block face plate, Insert one end of the Anti-splash threshold (#15) fully into the Guide block (#12) and replace the guide block face plate. Align the Anti-splash threshold (#15) with the front edge of the shower base or threshold. Cover the other end of the Anti-splash threshold (#15) with the Threshold cap (#16) against the wall.
NOTE: Do not attach the handle to the door glass until instructed to do so. Do not attempt to lift the door glass with the handle as this may result in damage to the glass and/or serious personal injury. 1 2 set screw 21. Attach the two Rollers (#04) to the Glass door (#05) with the wheels facing outside of the shower and the set screw facing the top for easier access.
23. Position the Door Stoppers (#01) and screw them tightly to the Upper Guide Rail (#03). NOTE: The Door stoppers (#01) must be positioned correctly to prevent the handle from contacting the Stationary glass (#02) (48”, 60” & 72“ models) and to stop the Glass door (#05) in a position that allows the bumper strip to create a seal with the wall, but does not allow the door glass to bang into the wall (48”& 60” models). Fig 24 24.
Enigma Roller adjustment procedure for Enigma and Enigma-X To achieve minimal clearance beneath the door glass without making contact with the bottom guide block and creating a good seal with the wall. Have at least two 3/16” shims or wedge shims (to maintain space beneath the door glass) and an assistant available to help with this procedure. You should adjust only one wheel at a time and you may need to perform these steps more than once to get the desired results.
Product Maintenance BASES and BACKWALLS: To ensure a long life for your acrylic back walls: wipe them off after each use with a soft cloth. To clean the acrylic back walls use non-abrasive sprays or cream based cleaners. Never use abrasive cleansers, metal brushes or scrapers that could scratch or dull the surface. GLASS: To ensure long lasting life for your glass shower products: wipe them off after each use with a soft cloth.
TEL: 866-731-2244 FAX: 866-857-3638 DREAMLINE.COM For more information on DreamLine® Shower Doors and Enclosure please visit DreamLine.