Installation&Assembly

3- If unit is not equipped with safety pilot, replace
brass elbow in burner pipe on the left side of the
burner pan, and brass hex plug in burner pipe
on the right side of burner pan. Use pipe dope
or Teflon tape for this operation. Continue
installation (step 3 - page 2).
4- If unit is not equipped with safety pilot,
pilot
must also be disassembled and reassembled
for left side installation. Refer to figure 5 for
parts identification.
PILOT ASSEMBLY Conversion (Fig. 5)
a– Disconnect pilot and thermocouple tubing at
pivot valve.
b– Remove spacer (or air mixer, if converted for
use with LP gas) from side of pilot valve. Pull
heat shield away from the pilot valve.
c– Flip pilot valve so that bottom is on top and
gas connection is now positioned correctly for
left-side entry into burner/pan assembly.
OPERATION NOTE
When this decorative log set is used in a fireplace
equipped with a combustion air kit and glass
doors, the glass doors should remain open
during
log set operation. This will maximize the radiant
heat provided to the surrounding area and mini-
mize overheating of any valve installation. The
glass doors may be closed with the log set is not
being used.
d– Slide heat shield over brass burner tube
connection and re-secure by reinstalling
spacer (or air mixer).
e– Reposition copper thermocouple tubing so
that tubing can be reconnected at the back of
the pilot valve. Reconnect pilot tubing in the
side of the pilot valve.
NOTE– After the unit has been converted for
left-side gas supply, the gas control knob will
be upside down when installed correctly.
5– Reinstall safety pilot assembly in burner pipe on
the left side of burner pan.
6- Install the brass hex plug in burner pipe on the
right side of the burner pan.
7- Continue with installation (step 3– page 2).
ORIFICE REPLACEMENT - 18” LOG SETS
1- Loosen the connection between the burner/pan
assembly and the safety pilot valve.
2- Remove the existing brass spacer from pilot
valve assembly.
3- Remove existing gas orifice from pilot valve.
4- Install appropriate replacement pilot orifice.
NOTE- Use larger #42 orifice for 24” or 30” log
sets and smaller #43 orifice for 18” log sets.
5- Install brass air mixer with lock washer on both
sides( all provided in changeover kit) in place of
brass spacer.
6- Unscrew thermocouple tubing from back of pilot
valve. Locate and remove existing orifice and
install replacement orifice provided in kit.
7- Continue with installation (step 3 on page 2).
WHAT TO DO IF YOU SMELL GAS:
1– Do not try to light any appliance.
2– Extinguish and open flames.
3– Do not touch any electrical switch; do not
use any phone in your building.
4– Immediately call your gas supplier from a
neighbor’s phone. Follow the gas
supplier’s instructions.
5– If you cannot reach your gas supplier, call
the fire department.
IMPORTANT
A safety pilot valve is required in all propane gas
applications.
FIGURE 5
Page 4