Installation&Assembly

Page 6
ANSI Z21160
MATCH LIGHT NATURAL GAS
LOG SET FRONT WIDTH DEPTH HEIGHT MINIMUM VENT INPUT MINIMUM INPUT MAXIMUM ORIFICE BTU/HR
SIZE IN INCHES IN INCHES IN INCHES IN SQUARE INCHES GAS PRESSURE GAS PRESSURE SIZE INLET
18" 24" 16 16 39 7"W.C. 10.5"W.C. 22 60000
21" 27" 16 16 44 7"W.C. 10.5"W.C. 22 60000
24" 30" 16 16 48 7"W.C. 10.5"W.C. 18 72000
30" 36" 16 16 58 7"W.C. 10.5"W.C. 18 72000
36" 42" 16 16 62 7"W.C. 10.5"W.C. 14 80000
42" 48" 16 16 68 7"W.C. 10.5"W.C. 14 80000
NATURAL GAS MANUAL SAFETY PILOT
LOG SET FRONT WIDTH DEPTH HEIGHT MINIMUM VENT INPUT MINIMUM INPUT MAXIMUM ORIFICE BTU/HR
SIZE IN INCHES IN INCHES IN INCHES IN SQUARE INCHES GAS PRESSURE GAS PRESSURE SIZE INLET
18" 24" 16 16 39 7"W.C. 10.5"W.C. 22 60000
21" 27" 16 16 44 7"W.C. 10.5"W.C. 22 60000
24" 30" 16 16 48 7"W.C. 10.5"W.C. 18 72000
30" 36" 16 16 58 7"W.C. 10.5"W.C. 18 72000
36" 42" 16 16 62 7"W.C. 10.5"W.C. 14 80000
42" 48" 16 16 68 7"W.C. 10.5"W.C. 14 80000
LIQUID PROPANE SAFETY PILOT
LOG SET FRONT WIDTH DEPTH HEIGHT MINIMUM VENT INPUT MINIMUM INPUT MAXIMUM ORIFICE BTU/HR
SIZE IN INCHES IN INCHES IN INCHES IN SQUARE INCHES GAS PRESSURE GAS PRESSURE SIZE INLET
18" 24" 16 16 39 11"W.C. 14"W.C. 42 60000
21" 27" 16 16 44 11"W.C. 14"W.C. 42 60000
24" 30" 16 16 48 11"W.C. 14"W.C. 37 72000
30" 36" 16 16 58 11"W.C. 14"W.C. 37 72000
36" 42" 16 16 62 11"W.C. 14"W.C. 35 80000
42" 48" 16 16 68 11"W.C. 14"W.C. 35 80000