Use and Care Manual

LR117
nd out how to protect yourself and your
family by contacting the National Lead
I
nformation Hotline at 1-800-424-LEAD or
log on to www.epa.gov/lead.
S
TIR THOROUGHLY BEFORE AND
DURING APPLICATION. DO NOT THIN.
Paint only when air and surface temperatures
are 50°F or higher. Apply Latex Base
DRYLOK Masonry Waterproofer directly on
bare masonry. Apply rst coat with DRYLOK
BRUSH or good quality nylon bristle brush
working the WATERPROOFER into the
pores of the masonry - avoid excessive
brushing (see COVERAGE). APPLY TWO
COATS. Allow to dry 3 hours between
coats. e second coat may be applied by
brush, roller or spray. For information on
spray application, write UGL and ask for
Spray Specication Sheet D-88 or visit
www.ugl.com.
If leaking is still present aer two coats, it
indicates that pores or pin holes are still
open. Paint these areas again. When painting
the inside of concrete sh ponds and non-
potable water tanks, allow Latex Base
DRYLOK Masonry Waterproofer to dry at
least one week, ll with water.
If desired, a high quality latex paint can be
applied over DRYLOK aer 24 hours for
decorative purposes.
Contains Crystalline Silica which can cause
cancer. (Risk of cancer depends on duration
and level of exposure.)
Use only with adequate ventilation. Do not
breathe dust, vapors or spray mist.
Vapor harmful. May aect the brain or
nervous system causing dizziness, headache
or nausea. Causes eye, nose and throat
irritation. May be harmful if absorbed
through skin. Harmful if swallowed.
NOTICE: Reports have associated repeated
and prolonged occupational overexposure
to solvents with permanent brain and
nervous system damage. Intentional misuse
by deliberately concentrating and inhaling
the contents may be harmful or fatal. Ensure
fresh air entry during application and drying.
If you experience eye watering, headache or
dizziness or if air monitoring demonstrates
v
apor/mist levels are above applicable limits,
wear an appropriate, properly ed
respirator (NIOSH approved) during and
aer application. Avoid exposure to dust by
w
earing an appropriate (NIOSH approved)
particulate respirator during sanding. Follow
r
espirator manufacturers directions for
respirator use. Close container aer each
use. Do not get in eyes, on skin or clothing.
Wash thoroughly aer handling.
is product contains a chemical known to
the State of California to cause cancer.
KEEP OUT OF REACH OF CHILDREN.
DO NOT TAKE INTERNALLY.
KEEP FROM FREEZING.
EYES: Flush immediately with large amounts
of water for at least 15 minutes. Consult a
physician if irritation persists..
SKIN: Wash aected areas with soap and
water. Consult a physician if irritation
persists.
INGESTION: Give 1 or 2 glasses of water. If
individual is drowsy or unconscious do not
give anything by mouth. Consult a physician,
medical facility or poison control center for
advise about whether to induce vomiting.
INHALATION: Remove to fresh air.
For additional health and safety information
please refer to the “Safety Data Sheet”.
United Gilsonite Laboratories (UGL®)
warrants DRYLOK® Latex Base Masonry
Waterproofer, when applied according
to directions on a properly prepared bare
masonry surface, will provide a waterproof
coating for ten (10) years from the date of
application, warranty includes subsequent
owners. ere are no other warranties that
extend beyond this warranty. is warranty
shall not apply when the waterproofer fails
due to improper product application,
failure to follow label directions,
inadequate surface preparation, cracked
structural surfaces, reoccurring
efflorescence or any conditions not
foreseen by UGL. Two coats of DRYLOK
Latex Base Waterproofer are required to
assure warranted waterproong. Label
directions are as complete as possible, but
cannot encompass all conditions,
a
pplications and/or surfaces. In the event
that the coating fails, your remedy is
limited to either replacement of the
product purchased or refund of the
p
urchase price. is is the exclusive
remedy. For warranty fulllment, return
u
sed product container and sales receipt
to UGL, Technical Customer Service, 1396
Jefferson Ave., Dunmore, PA, 18509. THIS
LIMITED WARRANTY EXCLUDES ALL
OTHER EXPRESS OR IMPLIED
WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR USE
OR PURPOSE. UGL will in no event be
liable for any incidental or consequential
damages. Some States do not allow
limitations on how long an implied
warranty lasts or the exclusion or
limitations of incident or consequential
damages, so the above limitations or
exclusions may not apply to you. is
warranty gives you specic legal rights, and
you may also have other rights which vary
from State to State.
Latex Base DRYLOK has been tested to
ASTM D-7088 Resistance to Hydrostatic
Pressure and ASTM D-6904 Resistance to
Wind Driven Rain.
Latex Base Waterproofer
Ready Mixed Colors White Gray Beige Blue
1 QT. 4/Case . . . . . . . . . . . . . . . .27512 n/a n/a n/a
1 GAL. 2/Case . . . . . . . . . . . . . . . .27513 27613 27713 27813
2 GAL. 1/Case . . . . . . . . . . . . . . . .27514 n/a n/a n/a
5 GAL. 1/Case . . . . . . . . . . . . . . . .27515 27615 27715 27815
DISCLAIMER:This information is furnished without warranty,
representation, inducement or license of any kind, except that it
is accurate to the best of UGLs knowledge, or obtained from
sources believed by UGL to be accurate, and UGL does not
assume any legal responsibility for use or reliance upon same.
Before using any product, read the label.
NOTE: COLOR SWATCHES ARE REPRESENTATIONAL ONLY.