CONTROL AB220A5111 0 I P E + - >> KL2334a LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS No. 402292 FRANKL & KIRCHNER GMBH & CO KG English EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS SINGAPORE PTE. LTD.
EFKA AB220A5111 CONTENTS Page 1 Table of Adapter Cords 5 2 Putting into Service 6 3 Setting and Putting into Service with the Aid of the Fast Installation Routine (SIR) 7 4 Operating Elements and Socket Connectors 8 4.1 4.2 4.3 4.4 Position of Operating Elements and Displays Position of the Socket Connectors Connection Diagram Connection of a Sewing Light with Transformer 8 9 10 13 5 Connection Scheme of SM210A Stepping Motor Control 14 5.
EFKA AB220A5111 1 Table of Adapter Cords ATTENTION! Before switching functional sequences, detach cables from the inputs and outputs! Please ensure that the machine installed provides the functional sequence to be set! Then proceed with the setting using parameter 290! Setting the functional sequence using parameter 290 Mode Designation Adapter Power transistors è 0 VR VR VR VR VR VR VR VR FA1 FA1 + FA1 + FA1 FA1 + FL FL FL FL FL FL FL FL FL FA-R FA-R FA-R STV M1 STV STV STV FA FA FA FA FA F
EFKA AB220A5111 6 Explanation of letter symbols of the previous page and chapter ”Timing Diagrams“ Outputs: FL VR FA FA2 FA-V FAU FSPL FW ML/NK RB KB MST PD≥1 PD=0 L-STL FZ IMP LFA = Sewing foot lifting = Backtacking = Thread trimmer = Thread trimmer pos. 1A...2 = Thread trimmer forward = Bobbin thread trimmer = Thread tension release = Thread wiper = Machine running / Needle cooling = Chain blowing in opposite direction = Chain blowing = Machine at standstill = Pedal steps 1...
EFKA AB220A5111 3 Setting and Putting into Service with the Aid of the Fast Installation Routine (SIR) The Fast Installation Routine (SIR) passes through all parameters necessary for programming the functional sequence and the positions.
EFKA AB220A5111 8 4 Operating Elements and Socket Connectors 4.
4.2 Position of the Socket Connectors B2 Socket for commutation transmitter B18 Socket for light barrier module / Hall sensor module / EFKANET (Adapter cord 1113229 in case of multiple assignment) B41 EFKA AB220A5111 B41 M B41 Socket for motor power supply B80 B2 M B80 B776 Socket for actuator B2 EB... B18 B776 LSM... V8 . .
EFKA AB220A5111 4.
EFKA AB220A5111 Inputs switched to +24V ATTENTION! When connecting the outputs, ensure that a total power of 96VA constant load will not be exceeded! 1) 2) 3) 4) *) Nominal voltage 24V, no-load voltage max. 30V momentarily after power on Transistor output with open collector max.
EFKA AB220A5111 POS2 OUT POS IN G1/G2 OUT TXD/RXD LSM IN LSM002 HSM001 12 - Output for position 2 Input for positions (e.g. connection of a sensor) Output of generator impulses Serial transmission lines Possibility of connecting a light barrier module to socket B18/8 (If parameter 239 = 0, the light barrier function is selected. Identification of the signal when switched to 0V.) - Reflection light barrier module - Hall sensor module If parameter 239 is set to 1...
EB.. Pedal step è Input A Input B Input C Input D 4.
EFKA AB220A5111 14 5 Connection Scheme of SM210A Stepping Motor Control mot V810/V820 DC1500/1550 variocontrol820 P E variocontrol810 1 2 3 4 5 6 7 8 9 10 11 P 12 E + 2 3 4 5 6 1 2 3 4 1 M 1 4 S M0 1 1 B41 B5 M B41 M B5 mot 1 B2 B776 B80 M B2 B776 EB... V8 . . B18 B19 B18 B19 control B18 B776 LSM... V8 . . B18 B80 B776 LSM... Nr.1113172 ST2 ST1 ST2 ST1 0 SM210.... I AB220A.... AB320A.... KL2511 The AB220A.... control (B18) and the SM210A.
5.1 EFKA AB220A5111 Adapter Cords Adapter cord for AISIN models AD3XX, AD158, 3310 and EK1 Setting the functional sequence Setting the functions of the keys Nr.
EFKA AB220A5111 16 Adapter cord for BROTHER model FD3 B257 Setting the functional sequence Setting the functions of the keys Thread trimming mode Input in1 Input in3 Input in4 Input in5 è è è è è Set parameter 290 Set parameter 240 Set parameter 242 Set parameter 243 Set parameter 244 = 5 = 7 = 18 = 16 = 17 Nr.
EFKA AB220A5111 Adapter cord for DÜRKOPP ADLER models 210, 270 Setting the functional sequence Setting the functions of the keys è è è è è Thread trimming mode Input in1 Input in3 Input in4 Input in5 Set parameter 290 Set parameter 240 Set parameter 242 Set parameter 243 Set parameter 244 = 0 = 16 = 1 = 3 = 17 Nr.
EFKA AB220A5111 18 Adapter cord for JUKI model 5550-6 Setting the functional sequence Setting the functions of the keys è è Thread trimming mode Input in1 Nr.
EFKA AB220A5111 Adapter cord for JUKI model LU1510-7 Setting the functional sequence Setting the functions of the keys (Automatic setting) Thread trimming mode Input in1 Input in3 Input in4 Input in6 Input in7 è è è è è è Set parameter 290 Set parameter 240 Set parameter 242 Set parameter 243 Set parameter 245 Set parameter 246 = = = = = = Nr.
EFKA AB220A5111 20 Adapter cord for KANSAI model RX9803 Setting the functional sequence Setting the functions of the keys ST2 SUB- D- 37 20 19 +5V +5V 1 LSP 2 0V 3 4 0V 7 in1 +24V 1 16 +24V FA 2 17 +24V +24V 3 18 Set parameter 290 Set parameter 240 +24V FW 4 +24V 5 ML 6 26 +24V 27 M3 32 M5 1 35 FL 2 37 M1 1 2 3 6 3 5 2 4 1 37 +24V 3 FL 4 1 2 3 4 *) = 5 = 7 Nr.
EFKA AB220A5111 Adapter cord for PFAFF models 563, 953, 1050, 1180 without thread monitor Setting the functional sequence Setting the functions of the keys è è è Thread trimming mode Input in4 Input in5 Nr.
EFKA AB220A5111 22 Adapter cord for PEGASUS models W500/UT, W600/UT/MS with or without stitch condensing Setting the functional sequence Setting the functions of the keys è è Thread trimming mode Input in1 Set parameter 290 Set parameter 240 = 5 = 7 Nr.
EFKA AB220A5111 Adapter cord for PEGASUS model MHG Setting the functional sequence Setting the functions of the keys è è è è è Thread trimming mode Input in1 Input in2 Input in3 Input in4 +5V in4 1 0V 2 1 ST2 20 SUB- D- 37 1 19 = = = = = Nr.
EFKA AB220A5111 24 Adapter cord for RIMOLDI model F27 Setting the functional sequence è Thread trimming mode Set parameter 290 = 5 Nr.
EFKA AB220A5111 Adapter cord for UNION SPECIAL models CS100 and FS100 Setting the functional sequence Setting the functions of the keys è è è Thread trimming mode Input in1 Input in3 Set parameter 290 Set parameter 240 Set parameter 242 = 4 = 6 = 6 Nr.
EFKA AB220A5111 26 Adapter cord for UNION SPECIAL model 34700 with stitch lock Setting the functional sequence Setting the functions of the keys Thread trimming mode Input in8 Input in9 Nr.
EFKA AB220A5111 Adapter cord for UNION SPECIAL models 34000 and 36200 Setting the functional sequence Setting the functions of the keys Thread trimming mode Input in1 Input in3 Input in4 Input in5 Nr.
EFKA AB220A5111 28 Adapter cord for YAMATO chainstitch machines VC series Setting the functional sequence Setting the functions of the keys è è Thread trimming mode Input in1 Set parameter 290 Set parameter 240 = 5 = 7 Nr.
EFKA AB220A5111 Adapter cord for YAMATO backlatch machine model ABT3 Setting the functional sequence Setting the functions of the keys (Automatic setting) è è è Thread trimming mode Input in1 Input in3 Set parameter 290 Set parameter 240 Set parameter 242 = 9 = 6 = 10 Nr.
EFKA AB220A5111 30 6 Timing Diagrams Mode 0 (lockstitch) - 1 1/ 2 0 - 1 + - 2 n n3 n2 n1 n2 0 12 3 12 3 POS.1 n4 01 2 n7 12 3 ST2/ 20 POS.
EFKA AB220A5111 Mode 2 (lockstitch) - 1 1/ 2 0 - 1 + - 2 n6 n n3 n2 n1 n4 01 23 POS.1 0 12 n7 n7 n1 n1 3 ST2/ 20 SSc POS.
EFKA AB220A5111 32 Mode 3 (lockstitch) - 1 1/ 2 0 - 1 + - 2 n n3 n2 0 12 3 12 3 POS.1 n10 n2 12 34 56 7 n4 n7 0 12 1 2 n7 3 ST2/ 20 tFA POS.
EFKA AB220A5111 Mode 4 (chainstitch) - 1 1/2 0 + - 1 - 2 n n3 n2 01 23 45 67 POS.1 n1 n4 n7 012 3 4 5 ST2/ 20 POS.
EFKA AB220A5111 34 Mode 5 (chainstitch) - 1 1/ 2 0 - 1 + - 2 n6 n 01 POS.1 n3 n2 n1 n4 23 n7 0 12 31 2 ST2/ 20 SSc POS.
EFKA AB220A5111 Mode 5 (chainstitch) Union Special, bag sewing machine - + 1 1/2 0 - 1 - 2 n6 n n2 n1 01 2 POS.1 ST2/ 20 SSc POS.2 ST2/ 21 t3 FL t4 t5 kdF ST2/ 35 STV ST2/ 34 M 2 (IMP) ST2/ 28 kt2 kd3 M 3 (BR) ST2/ 27 kt3 M 5 (ML) ST2/ 32 M 6 (MST) ST2/30 in1...i10 ST2/ .. 0256/ MODE- 5a Mark SAk in1...
EFKA AB220A5111 36 Mode 4, 5, 6 or 7 (function “unlocking the chain” with light barrier) 1 1/2 - 0 - 1 - 2 + n n2 POS.1 n5 n1 n1 0 345 67 ST2/ 20 POS.2 drd ird ST2/ 21 t3 FL LS t4 t5 ST2/ 35 STV ST2/ 34 M5 (ML) ST2/ 32 M6 (MST) ST2/30 LS ENTK 0256/ ENTK- 1 Mark drE Frd in7 in8 in..
EFKA AB220A5111 Mode 4, 5, 6 or 7 (function “unlocking the chain”) 1 1/2 0 - 1 - 2 - + n n2 n1 n2 n1 n1 n1 POS.1 ST2/ 20 POS.2 drd Ird drd Ird ST2/ 21 t3 FL ST2/ 35 STV ST2/ 34 M5 (ML) ST2/ 32 M6 (MST) ST2/30 ENTK 0256/ ENTK- 2 Mark drE Frd in7 in8 in..
EFKA AB220A5111 38 Mode 6 (chainstitch with fast scissors) parameter 232 = 1 - 1 1/ 2 0 - 1 + - 2 n6 n 01 POS.1 n3 n2 n6 n7 23 01 n3 n2 n7 23 ST2/ 20 SSc POS.
EFKA AB220A5111 Mode 7 (overlock) parameter 232 = 0 (tape cutter) / parameter 018 = 0 (seam end with stop) - 1 1/ 2 0 - 1 + - 2 n n3 n2 n1 n2 0 1 2 3 4 56 78 POS.1 n5 n4 n7 1 34 512 3456 7 ST2/ 20 POS.
EFKA AB220A5111 40 Mode 7 (overlock) parameter 232 = 1 (fast scissors) / parameter 018 = 0 (seam end with stop) - 1 1/ 2 0 + - 1 - 2 n n3 n2 n1 n2 0 12345678 POS.1 n5 n4 n7 1 3 4 5 1 2 3 4 5 6 7 ST2/ 2 0 POS.
EFKA AB220A5111 Mode 7 (overlock) parameter 232 = 0 (tape cutter) / parameter 018 = 1 (seam end without stop) 1 1/ 2 0 - 1 - 2 - + n n3 n2 01 234 56 POS.1 n4 n3 1 23 456 7 n2 n1 n7 01 234 56 ST2/ 20 POS.
EFKA AB220A5111 42 Mode 8 (backlatch Pegasus) - 1 1/ 2 0 - 1 + - 2 n6 n 01 POS.1 n2 n12 n1 n6 2 01 n2 n1 2 ST2/ 20 SSc POS.
EFKA AB220A5111 Mode 9 (backlatch Yamato) - 1 1/2 0 - 1 + - 2 n6 n 01 POS.1 n2 n12 n1 n6 2 0 1 n2 n9 n1 2 ST2/ 20 SSc POS.
EFKA AB220A5111 44 Mode 10 (lockstitch) - 1 1/2 0 + - 1 - 2 n n3 n2 01 23 45 67 POS.1 n1 n4 n7 012 3 4 5 ST2/ 20 POS.
EFKA AB220A5111 Mode 14 (lockstitch) - 1 1/ 2 0 - 1 + - 2 n n3 n2 n1 n2 0 12 3 12 3 POS.1 n4 01 2 n7 12 3 ST2/ 20 POS.
EFKA AB220A5111 46 Mode 15 (Pegasus SSC100) sequence when high lift for walking foot is Off / start of seam with light barrier covered - 1 1/ 2 0 - 1 + - 2 n n2 POS.1 n1 1 3 4 5 6 7 ST2/ 20 POS.
EFKA AB220A5111 Mode 15 (Pegasus SSC100) sequence when high lift for walking foot is Off / start of seam with light barrier uncovered - 1 1/ 2 0 + - 1 - 2 n n2 n1 n2 POS.1 n1 1 3 4 5 6 7 ST2/ 20 POS.
EFKA AB220A5111 48 Mode 15 (Pegasus SSC100) sequence when high lift for walking foot is On - 1 1/ 2 0 - 1 + - 2 n n2 POS.1 n1 1 3 4 5 6 7 ST2/ 2 0 POS.
EFKA AB220A5111 Mode 16 (feed-off-the-arm machine) without automatically unlocking the chain with tape cutter (232 = 0) - 1 1/ 2 0 - 1 + - 2 n n3 n2 n1 n2 01 23456 78 POS.1 n5 n4 1 3 4 5 1 2 3 4 5 6 n7 7 ST2/ 20 POS.
EFKA AB220A5111 50 Mode 16 (feed-off-the-arm machine) automatically unlocking the chain with tape cutting / 8 key on V820 On - 1 1/ 2 0 + - 1 - 2 n n2 n1 n2 n5 n4 n7 1 3 4 5 1 2 3 4 5 1 POS.1 2 3 ST2/ 2 0 drd ird POS.
EFKA AB220A5111 Mode 17 (stitch lock Pegasus) - 1 1/ 2 0 - 1 + - 2 n n2 n7 n7 n2 n1 n7 POS.1 ST2/ 20 dr POS.
EFKA AB220A5111 52 Mode 20 (lockstitch Juki LU1510-7) - + 1 1/2 0 - 1 - 2 n n3 n2 n11 n9 n10 0 12 3 12 3 POS.1 n2 n4 n7 0 12 1 2 3 ST2/ 20 drd ird POS.
EFKA AB220A5111 Mode 21 (stitch lock) - 1 1/ 2 0 - 1 + - 2 n3 n n2 n1 n4 01 2 3 POS.1 n7 n7 01 23 ST2/ 20 tFA POS.
EFKA AB220A5111 54 Mode 23 (lockstitch) - 1 1/ 2 0 - 1 + - 2 n n3 n2 0 1 2 3 1 2 3 POS.1 n10 n2 1 2 3 4 5 6 7 n4 n7 0 1 2 1 2 n7 3 ST2/ 20 tFA POS.
EFKA AB220A5111 Mode 24 (Pegasus MHG-100) “bottom hemming“ On Power on 1 1/ 2 0 + - 1 - 2 n n2 n1 n2 n1 n2 0 POS.1 n5 n7 3 4 5 6 ST2/ 2 0 POS.
EFKA AB220A5111 56 Mode 24 (Pegasus MHG-100) “sleeve hemming“ On Power on 1 1/ 2 0 + - 1 - 2 n n2 n1 n2 n1 n2 0 POS.1 n5 n7 3 4 5 6 ST2/ 20 POS.
EFKA AB220A5111 7 List of Parameters 7.1 Preset Values Depending on Mode The preset values which are different in the various modes are listed in the table below. When switching the mode by means of parameter 290, these values change automatically.
EFKA AB220A5111 58 Supplier Level Mode è Parameter ** ** ** ** ** ** ** ** ** ** ** ** ** 0 2 3 4 5 6 7 8 9 10 14 15 16 17 20 21 23 24 200 201 202 203 204 205 206 207 209 210 211 212 213 234 240 241 242 243 244 - - 13 7 1 22 16 160 350 100 12 6 3 - - - - 0 0 6 10 1 - 0 0 6 38 34 - 12 240 150 100 100 12 - 16 - 100 14 15 15 15 - - 13 31 32 - 200 - 50 80 200 100 50 10 100 0 200 50 13 07 01 0 16 6 14 28 22 - 245 246 247 248 249 250 253 255 260 262 269 270 271 272 274 2
7.2 EFKA AB220A5111 Operator Level The preset values of the following list of parameters refer to the setting of parameter 290 = 0. Parameter Designation 000 c2 - Number of stitches of start backtack forward - Number of stitches of start stitch condensing without stitch regulator - Number of stitches of end counting “chain Unit stitches max 254 min 0 Preset 2 *) Ind.
EFKA AB220A5111 60 Operator Level Parameter Designation Unit 019 -Pd 0 = Pedal in pos. –1 disabled in the seam. With pedal in pos. –2 in the seam, only sewing foot lifting is possible. (Function only if parameter 009 = 1) 1 = Pedal in pos. –1, sewing foot lifting disabled in the seam. 2 = Pedal in pos. –2, thread trimming disabled. (Function only if parameter 009 = 1) 3 = Pedal in pos. –1 and –2 enabled in the seam. 4 = Pedal in pos. –1 and –2 blocked in the seam.
7.3 EFKA AB220A5111 Technician Level Code no. 190 with control operation Code no.
EFKA AB220A5111 62 Technician Level Code no. 190 with control operation Code no. 1907 with control panel operation Parameter 132 LSS 0 = 133 LSE 134 135 136 137 139 141 SSt SrS FAr hP nIS SGn 142 SFn 143 kSA 144 kSE *) **) Designation Unit Machine start possible with light barrier uncovered or covered. 1= Machine start blocked with light barrier uncovered if parameter 131 = 1. Machine start blocked with light barrier covered if parameter 131 = 0.
EFKA AB220A5111 Technician Level Code no. 190 with control operation Code no.
EFKA AB220A5111 64 Technician Level Code no. 190 with control operation Code no.
EFKA AB220A5111 Technician Level Code no. 190 with control operation Code no. 1907 with control panel operation Parameter Designation Unit 188 hP Minimum speed level for high lift for walking foot Maximum speed level for high lift for walking foot Assignment of maximum speed (parameter 111) and minimum speed (parameter 117) to the 21 speed levels depending on high lift. Display example: 2740 max 21 21 min 1 1 Preset 0 1 0 0 0 0 0 0 0 0 0 0 Ind.
EFKA AB220A5111 66 Technician Level Code no. 190 with control operation Code no.
7.4 EFKA AB220A5111 Supplier Level Code no. 311 with control operation Code no. 3112 with control panel operation Parameter Designation Unit max 200 t1 Delay until speed release after start backtack ms 500 201 t2 Sewing foot lift switch-on delay with half ms 500 heelback 202 t3 Start delay after disabling the sewing foot ms 500 lift signal 203 t4 Time of full power of sewing foot lifting ms 600 204 t5 Holding power for sewing foot lifting % pa. 254 1...
EFKA AB220A5111 68 Supplier Level Code no. 311 with control operation Code no. 3112 with control panel operation Parameter Designation Unit max 237 tkS Switch-off delay for chain suction at the ms 2550 seam end, if parameter 022 = 2. 238 EnP Software debouncing for all inputs: 1 0 = No debouncing 1 = With debouncing 239 FEL Selection of the input function on socket B18/5 47 0 = Light barrier function, if 009 = 1 All other functions as with parameter 240.
EFKA AB220A5111 Supplier Level Code no. 311 with control operation Code no. 3112 with control panel operation Parameter 240 in1 29 = 241 in2 242 in3 243 in4 244 in5 245 in6 246 in7 247 in8 248 in9 249 i10 *) Designation Unit “Hemmer foot” signal Off (see parameter 296), function effective only in the seam 30 = High lift for walking foot, if sewing foot is On 31 = Function “speed limitation bit0” (speed n11) 32 = Function “speed limitation bit1” (speed n10) (bit0 + bit1 = speed n9).
EFKA AB220A5111 70 Supplier Level Code no. 311 with control operation Code no. 3112 with control panel operation Parameter 250 iFA 251 FSA 252 FSE 253 tFA 254 EF255 EV- 256 kt6 257 c7 258 c8 260 ihr 261 262 nhr dhr 263 ihP 264 iS1 265 266 ktS inr 269 PSv *) **) Designation Unit Thread trimmer activation angle degrees Switch-off delay of thread tension release ms Switch-on delay angle of thread tension release degrees Stop time for thread trimmer ms Upper limit (pa.
EFKA AB220A5111 Supplier Level Code no. 311 with control operation Code no. 3112 with control panel operation Parameter Designation Unit 270 PGm Connection of a sensor e. g. light barrier sensor to light barrier socket B18/7. Selection of the desired function! 0 = The positions are generated by means of the transmitter incorporated in the motor and can be set by means of parameter 171. 1 = Setting the sensor to position 2. Set position 1 using parameter 271, starting from leading edge position 2.
EFKA AB220A5111 72 Supplier Level Code no. 311 with control operation Code no. 3112 with control panel operation Parameter Designation Unit 270 PGm Connection of a sensor e. g. light barrier sensor to light barrier socket B18/7. Selection of the desired function! 0 = Function as in table on previous page! 1 = Setting the sensor to position 2. Set position 1 using parameter 271, starting from trailing edge position 2. 2 = Setting the sensor to position 2.
EFKA AB220A5111 Supplier Level Code no. 311 with control operation Code no.
EFKA AB220A5111 74 Supplier Level Code no. 311 with control operation Code no. 3112 with control panel operation Parameter 290 FAM 0 = Designation Unit Lockstitch mode: (FA1, FA2, FA3, FA1+FA2); e. g. Brother Dürkopp Adler, Mitsubishi, Pfaff, Toyota »Slide-in strip for V810 and V820 = 1« 2 = Lockstitch mode: e. g. Singer (212 UTT) »Slide-in strip for V810 and V820 = 1« 3...= Lockstitch mode: e. g. Dürkopp Adler (models 767, N291) strip for V810 and V820 = 1« 4 = Chainstitch mode: e. g.
EFKA AB220A5111 Supplier Level Code no. 311 with control operation Code no. 3112 with control panel operation Note When selecting the trimming mode by means of parameter 290, the connected V810 or V820 control panel is automatically sensed and the corresponding slide-in strip number is selected by means of parameter 291 and 292, respectively. Should a different strip be inserted, its number can be set by means of parameter 291 and 292, respectively, after having selected the trimming mode.
EFKA AB220A5111 76 Supplier Level Code no. 311 with control operation Code no. 3112 with control panel operation Parameter Designation Unit 297 M11 Functions of signal M11 0 = Function according to setting of parameter 290. 1 = Signal M11 is switched on whenever the light barrier is uncovered (pa. 131 = 1) or covered (pa. 131 = 0) 2 = Signal M11 is switched on whenever the light barrier is covered (pa. 131 = 1) or uncovered (pa.
EFKA AB220A5111 Supplier Level Code no. 311 with control operation Code no.
EFKA AB220A5111 78 Supplier Level Code no. 311 with control operation Code no. 3112 with control panel operation Parameter Designation Unit 323 FLn 0 = Sewing foot is not lifted after power On 1 = Sewing foot is lifted after power On This function is enabled only if TEACH IN is On 324 ti 0 = TEACH IN Off 1 = TEACH IN On TEACH IN programming is possible only with V820. Execution of pattern is possible without V820.
EFKA AB220A5111 Parameter A1 301 302 303 304 305 308 309 A2 311 312 313 314 315 318 319 [ms] [ms] [St] [St] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 NA LS- D NE FA- E P=0 1) 2) 100 1 0 0 0 100 0 0 1 0 1 100 100 0 0 3 0 0 0 0 0 10 3 0 2 0 0 10 10 3 0 1 100 0 0 10 1 0 2 0 100 10 0 2 0 0 0 0 0 0 2 0 0 0 0 0 0 100 100 10 10 10 100 10 10 100 1) 2) 100 0 0 1 100 0 0 0 0 0 2 0 0 10 0 1 3 0 0 100 0 0 1
EFKA AB220A5111 80 8 Error Displays General Information On the control On the V810 On the V820 Signification A1 InF A1 InFo A1 Pedal not in neutral position, when turning the machine on A2 -StoP- blinking -StoP- blinking + symbol display Machine run blockage A3 InF A3 InFo A3 Reference position is not set A7 Symbol blinking Symbol blinking Bobbin thread monitor Programming Functions and Values (Parameters) On the control On the V810 On the V820 Signification Returns to 000 or to la
EFKA AB220A5111 9 Slide-in Strips for the V810/V820 Control Panels Slide-in strips for the V810 control panel Slide-in strips for the V820 control panel 1 R F R F R F 3 R F 4 2 F1 R 1 2 F2 F1 F2 F1 F2 5 6 F INSERT F1 DELETE F2 7 F1 1 1 1 2 2 2 F F F2 8 INSERT F1 DELETE F2 9 INSERT F1 DELETE F2 10 F INSERT F1 DELETE F2 KL2256e Note When changing the setting of parameters 291 / 292, the V810 / V820 functions change as well, save function keys F1 / F2 which
EFKA AB220A5111 For your notes: 82
For your notes: EFKA AB220A5111
FRANKL & KIRCHNER GMBH & CO KG SCHEFFELSTRASSE 73 – D-68723 SCHWETZINGEN TEL.: (06202)2020 – TELEFAX: (06202)202115 email: info@efka.net – http://www.efka.net OF AMERICA INC. 3715 NORTHCREST ROAD – SUITE 10 – ATLANTA – GEORGIA 30340 PHONE: (770)457-7006 – TELEFAX: (770)458-3899 – email: efkaus@efka.net ELECTRONIC MOTORS SINGAPORE PTE. LTD. 67, AYER RAJAH CRESCENT 05-03 – SINGAPORE 139950 PHONE: 7772459 – TELEFAX: 7771048 – email: efkaems@efka.