SECTION I: SPECIFICATIONS (cont.)
HL30SK 30 1.38 110 85 25 55,000 1.3 2.0
HL40SK 38 2.30 153 120 33 77,000 1.1 3.0
HL50SK 45 2.30 160 120 40 77,000 1.0 3.0
HL80SK 75 2.76 200 130 70 83,000 0.9 5.0
HL119SK 110 2.76 232 130 102 83,000 1.2 5.0
Model
Actual Tank
Volume (gal)
Coil Volume
(gal)
First Hour
Rating (gal)*
Continuous Draw
Rating (GPH)*
First Draw
Rating (gal)*
Minimum Coil
Output (BTU/Hr)**
Standby Loss
Rating (°F/hr)
Heat Source Friction
Loss (ft. w.c.)
T
able 2:
C
apacity & Performance
Capacities
Performance
HL30SK
107 @ 53,000 114 @ 57,000 117 @ 59,000 129 @ 67,000 132 @ 69,000 136 @ 71,000 139 @ 73,000
HL40SK
141 @ 69,000 165 @ 84,000 177 @ 92,000 171 @ 88,000 183 @ 96,000 195 @ 104,000 207 @ 111,000
HL50SK
148 @ 69,000 172 @ 84,000 184 @ 92,000 178 @ 88,000 190 @ 96,000 202 @ 104,000 214 @ 111,000
HL80SK
188 @ 76,000 212 @ 91,000 224 @ 98,000 221 @ 97,000 233 @ 104,000 245 @ 112,000 257 @ 119,000
HL119SK
220 @ 76,000 244 @ 91,000 256 @ 98,000 253 @ 97,000 265 @ 104,000 277 @ 112,000 289 @ 119,000
Model
180°F
6 GPM*
180°F
10 GPM*
200°F
6 GPM*
200
°F
10 GPM*
FIRST HOUR RATING (gal) @ Coil Output (Btu/hr)
Table 3: Performance (cont.)
NOTES:
* Based on 77°F rise with 58°F potable water inlet temperature at 8 GPM heat source flow rate. Heat source temperature was 180°F.
** Minimum Coil output based on continuous boiler operation over 30 minutes. See Section III for additional considerations.
All data obtained through testing in accordance with GAMA INDIRECT-FIRED WATER HEATER TESTING STANDARD IWH-TS-1_MARCH 2003
200°F
12 GPM*
200°F
8 GPM*
180°F
12 GPM*
NOTES:
First Hour Rating = First Draw + Continuous Draw
* Coil Input (temperatur
e, flow rate). Ratings based on 77°F rise with 58°F inlet potable water.
All data obtained through testing in accordance with GAMA INDIRECT
-FIRED W
A
TER HEATER TESTING STANDARD IWH-TS-1_MARCH 2003