Install Instructions

8
TERMINATIONS:
Horizontal Single Pipe (Fig.10)
1. Locate penetration in wall
2. Cut or cut and frame hole (Table 3)
3. Attach Inner Plate to wall
4. Attach / seal Outer Plate to outside wall
5. Line up keyway, slide black pipe (UV
Protected) or termination through
plates
6. If termination is used attach with screws
Align tabs with mounts
7. Add additional components to raise vent
level if desired (vent to be 12" above
grade or ave snow level)
8. Remove gasket and install Bird Guard
into end of pipe. (Fig.11)
9. Install Poly Pro venting system to/from
termination to appliance
Horizontal Twin Pipe (Fig.12)
1. Locate penetration
2. Cut or cut and frame hole (Table 3)
3. Attach interior wall plate to inside wall
4. Attach and seal exterior wall plate to
outside wall
5. Slide pipes through outer plate
6. Rotate pipes to slide pipe past keyway
7. Attach inner plate to wall
8. Attach and seal outer plate to outside
wall
9. Slide exhaust tip into exhaust pipe
10. Mount outer cover plate to exterior wall
plate.
11. install Poly Pro venting system to/from
termination to appliance
Horizontal Concentric (Fig.13)
1. Locate penetration
2. Cut hole (Table 3)
3. Attach and seal exterior exterior wall
plate onto outside wall
Figure 10
ALIGN TABS WITH
MOUNTS
GASKET
EXTERIOR
WALL PLATE
INTERIOR
WALL PLATE
Figure 12
POSITIONED
HORIZONTALLY
POSITIONED
VERTICALLY
AIR INLET PIPE
OUTER COVER PLATE
APPLY BEAD OF SILICON SEALANT
AROUND FEMALE END OF PIPE TO
SEAL AGAINST EXTERIOR WALL PLATE
INTERIOR
WALL PLATE
EXTERIOR WALL PLATE
EXHAUST TIP
EXHAUST PIPE
Figure 11
REMOVE GASKET
INSERT BIRD GUARD