Operation Manual

5.2 Sewing lamp transformer connection to network voltage
Caution! Risk of electric current injury!
The sewing lamp transformer is not switched off by the main switch
(EN 60 204-31)! At the sewing lamp installation and repair inside the
transformer box, e.g. at a fuse replacement, the network plug must be
disconnected from the network unconditionally.
The control boxes DAC basic/classic and Efka DA321G are equipped
with a terminal box for the connection of a sewing lamp external
transformer to the voltage 230V/AC or 24V/DC 1,5W (DAC).
A special adaptor 9870 001033 is supplied with the control box DAC
eco for the connection of the sewing lamp transformer.
A. The machine is equipped with the DAC basic/classic drive
Pull the plug out of the electric network socket!
Dismantle the terminal box plastic cover on the control box.
Connect the transformer cable of the sewing lamp according to the
instructions included in the operating manual of the DAC drive
(power supply terminals (L, N) for the transformer are parallel to
the power supply).
Before the back installation of the cover break the plastic blind with
a suitable tool to run the cable out of the terminal box.
16
LN