7 Pneumatic connection
CLASSIC machines with pneumatics.
Attention!
The special sewing machine’s operating pressure is 6 bar.
Mount the maintenance unit 1 to the s tand brace as shown in the
illustration.
Screw in the elbow fitting 2 (in the accessories) and connect the
hose 3 from the machine head to the elbow fitting 2.
Fix the connection hose 4 as shown in the illustration and connect
the other end with the coupling to the compressed air supply
system.
Raise and turn the handle 5 to set the pressure to 6 bar on the
manometer 6. Press the handle 5 again.
If the machine is equipped with the pneumatic driven sewing foot
with constant pressure, connect it to the maintenance unit as
shown in the picture below.
23
EN
1
2
5
6
3
4