Operating Guide

Changing / Inspecting the AVR
The carbon brushes in conjunction with the AVR regulates power from the generator. If the
generator is overheated or overloaded, the AVR may be damaged and require replacement.
Unbolt the AVR
Cut zipties
Disconnect AVR wire clip
Remove the 2 bolts of the AVR, located behind the power
panel.
Remove the back cover (see step 1 on page 53). Cut the zip
ties connecting the AVR to the brush system..
Disconnect the wire clip.
1.
2.
3.
53