Owner`s manual

Owner’s Manual – Prodigy 3
11
H1250 1250 Rev. I
9. Turn the knob to a higher number
for higher water temperatures or
a lower number for lower water
temperatures.
10. Set the test point pressure as per
page 12.
11. Replace the access panel and
ensure that it is rmly in position
before operating the appliance.
12. If the burner does not light at
the selected setting, the water
may already be at the selected
temperature.
Warning: Do not attempt to light if
the pilot is out and the knob is in the
“ON” position (one of the number
settings). Follow steps above.
Shutting Down The Water Heater
1. Turn the knob to “•” (off) position.
2. Turn water off at water isolating
valve.
Turning Off Gas To The Appliance
1. Turn the knob to “•” (off) position.
2. Turn off the gas isolation valve.
To maintain safety and efciency this
heater should be serviced annually by
an authorised service agent.
Models with “Eurosit” Gas Control
Commissioning Adjustments